  . . . . . . . . .3

USING THE AIR CONDITIONER

Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

CARE AND CLEANING

Air Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Outdoor Coils . . . . . . . . . . . . . . . . . . . . . . . . .7

INSTALLATION  

INSTRUCTIONS

  . . . . . . . . . . . . . . . . . . . . 8

TROUBLESHOOTING TIPS

 . . . . . . 16

Normal Operating Sounds  . . . . . . . . . . . . . 16

LIMITED WARRANTY

  . . . . . . . . . . . . . .17

CONSUMER SUPPORT

 . . . . . . . . . . . .18

OWNER’S MANUAL 

AND INSTALLATION 

INSTRUCTIONS

Содержание AEW14 Series

Страница 1: ...l Electric Company Manufactured under trademark license AIR CONDITIONER ROOM 49 5000084 09 18 GEA AEW14 AEW18 AEW24 SAFETY INFORMATION 3 USING THE AIR CONDITIONER Controls 4 CARE AND CLEANING Air Filt...

Страница 2: ...nto every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need...

Страница 3: ...pment and safety standards approved for use with this refrigerant DO NOT use equipment certified for R22 refrigerant only WARNING USE OF EXTENSION CORDS RISK OF FIRE Could cause serious injury or deat...

Страница 4: ...hours at its previous mode and fan settings Delay OFF When the air conditioner is on it can be set to automatically turn off in 1 to 24 hours How to set Press the Delay 1 24hr pad on the unit or the...

Страница 5: ...ts the unit to gradually change settings over an 8 hour period to allow for some increased energy efficiency during sleep hours The SLEEP mode is available only in COOL and FAN only settings Press the...

Страница 6: ...do not provide cooling a Set temperature cannot be entered The room temperature will appear in the display NOTE Auto Fan Speed cannot be used when in the Fan Only Mode Auto Fan Speed Set to Auto fan...

Страница 7: ...is recommended CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance Outdoor Coils The coils on the outdoor side of the air conditioner...

Страница 8: ...azard If the wall outlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet 6RPH PRGHOV UHTXLUH YROW protected with a t...

Страница 9: ...ail Sill angle bracket 2 Right accordion panel Foam top window gasket 1 Left accordion panel Side rail 2 PARTS INCLUDED Appearance may vary Top rail gasket 1 Type E bolt with nut 4 Type A screws 10 7...

Страница 10: ...reinstalling the front housing C Grasp the lower corners of the grille while pressing in on the case sides with your finger tips Pull out to release and lift it up NOTE Do not pull the bottom edge to...

Страница 11: ...conditioner from the case by gripping the base pan handle and pulling forward while bracing the case Do not pull or lift on the foam discharge area FRONT Do not pull or lift in this area damage to th...

Страница 12: ...nt the FDVH WR WKH ZLQGRZ VLOO XVLQJ W SH VFUHZV Drill pilot holes if necessary D Assemble the V support and V support bracket with Type F nut and bolt 5 PREPARE THE WINDOW AND INSTALL THE CASE contin...

Страница 13: ...ut the foam top window gasket to the window width J Stuff the foam between the glass and the window to prevent air and insects from getting into the room NOTE If the gasket supplied does not fit your...

Страница 14: ...257 17 7 5281 6 5 6 0867 5 167 72 1685 3523 5 5281 C Reinstall the control to the panel housing by replacing the 2 screws you removed earlier D Attach the front grille to the case by inserting the tab...

Страница 15: ...the hole location or make arrangements to install a receptacle C Place the case in the wall opening and place wood support strips between the case bottom and the flashing on both sides of the bottom...

Страница 16: ...hot When the air conditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace registers and cold air returns Cooling coils have iced up S...

Страница 17: ...or you may be required to bring the product to an XWKRUL HG SSOLDQFHV 6HUYLFH ORFDWLRQ IRU VHUYLFH Q ODVND WKH OLPLWHG ZDUUDQW H FOXGHV WKH FRVW RI VKLSSLQJ or service calls to your home 6RPH VWDWHV...

Страница 18: ...V WKDW DUH DYDLODEOH ZKLOH RXU warranty is still in effect You can purchase it on line anytime GE Appliances Services will still be there after your ZDUUDQW H SLUHV Q WKH 86 GEAppliances com extended...

Страница 19: ...y Fabricado bajo licencia de marca MANUAL DEL PROPIETARIO Y INSTRUCCIONES DE INSTALACI N INSTRUCCIONES DE SEGURIDAD 3 USO DEL ACONDICIONADOR DE AIRE Controle 4 CUIDADO Y LIMPIEZA Filtro de aire 7 Bobi...

Страница 20: ...creemos que usted tambi n Entre otras cosas el registro de su electrodom stico asegura que podamos entregarle informaci n importante del producto y detalles de la garant a cuando los necesite Registre...

Страница 21: ...refrigerante R22 ADVERTENCIA USO DE PROLONGADORES RIESGO DE INCENDIO Podr a ocasionar lesiones graves o la muerte 12 XVH XQ SURORQJDGRU FRQ HVWH FRQGLFLRQDGRU GH LUH GH Ventana 12 XVH SURWHFWRUHV FRQ...

Страница 22: ...condicionador de aire est apagado puede ajustarse SDUD TXH VH HQFLHQGD DXWRPiWLFDPHQWH GHQWUR GH D horas en el modo y configuraci n de ventilador anterior Delay OFF APAGADO Retardo Cuando el acondicio...

Страница 23: ...RGR GH KRUDV D ILQ GH permitir cierto incremento de eficiencia energ tica durante las horas de inactividad El modo SLEEP RUPLU Presione la tecla del modo SLEEP RUPLU OD OX VH encender El indicador del...

Страница 24: ...e no proporcionan enfriamiento no se puede introducir una temperatura Definida Aparecer en pantalla la temperatura ambiente NOTA La Velocidad de ventilador autom tica no puede utilizarse en el modo Fa...

Страница 25: ...ja Apague el acondicionador de aire y retire el enchufe del tomacorriente de la pared antes de limpiar 3DUD OLPSLDU XVH DJXD XQ GHWHUJHQWH VXDYH 1R XVH FORUR R materiales abrasivos Bobinas para exteri...

Страница 26: ...usar solamente tiene 2 tomas es su responsabilidad hacer que un t cnico lo reemplace por uno de tres tomas con conexi n a tierra OJXQRV PRGHORV UHTXLHUHQ YROWLRV GH FRUULHQWH alterna protegidos por u...

Страница 27: ...spuma superior de la ventana Panel de acorde n izquierdo 5LHO ODWHUDO 7RS UDLO JDVNHW Sello de la banda de OD YHQWDQD Sello del panel GH DFRUGHyQ Soporte angular SDUD DOIpL DU Trabas para PDUFRV 6RSRU...

Страница 28: ...O SDUD KDFHUOD PiV alta que la parte superior del marco de la ventana de tormentas o del marco vinilo P guelo firmemente con clavos o con tornillos proporcionados por el instalador PiV DOWR que el mar...

Страница 29: ...a bandeja inferior y tirando KDFLD DGHODQWH PLHQWUDV VH VXMHWD OD FDUFDVD 1R WLUH o levante el rea de descarga de poliestireno 4 PREPARE LA CARCASA C HVOLFH FDGD VRSRUWH SRU HO H WUHPR GH FDGD SDQHO c...

Страница 30: ...con oporte para bloqueo de ventana para otros tipos de ventanas Perfore orificios piloto si fuera necesario 5 PREPARE LA VENTANA E INSTALE LA CAJA D Enlace el soporte en V y la ficha del soporte en V...

Страница 31: ...puma superior de la ventana al ancho de la ventana J Rellene la espuma entre el vidrio y la ventana para evitar que aire e insectos se introduzcan en la habitaci n NOTA Si la junta provista no es adec...

Страница 32: ...6 85 5 81 21 1 7 55 8 C Reinstale el control en el espacio del panel reemplazando los 2 tornillos que retir previamente D Sujete la parrilla frontal a la carcasa introduciendo las leng etas de la par...

Страница 33: ...ntana B Aseg rese de que haya un tomacorriente cerca de la ubicaci n del orificio o efect e arreglos para instalar un tomacorriente C Coloque la carcasa en la abertura de la pared y coloque gu as de s...

Страница 34: ...acondicionador de aire El control de temperatura no est ajustado apropiadamente En los modelos con teclado En el modo Cool Fr o presione la tecla Reducci n En los modelos con botones gire la temperat...

Страница 35: ...leve el producto a una centro de servicio de GE Appliances autorizado para realizar la reparaci n En Alaska la garant a limitada excluye el costo de env o o las visitas de servicio a su casa Algunos e...

Страница 36: ...disponibles mientras su garant a a n est vigente La puede adquirir en cualquier momento a trav s de Internet Los Servicios de GE Appliances a n HVWDUiQ DOOt FXDQGR VX JDUDQWtD FDGXTXH Q 88 GEApplianc...