When a re-alarm does occur, the letter preceding the zone number will not be shown.
Resetting a zone in alarm
•
The LED of the area in alarm flashes red on the keypad (if the screen saver is not active).
•
The sirens are active (if programmed),
•
When an alarm occurs, the display
There Are No Alarms In This Area
disappears from the top
line. Instead you see:
Code:
Zones in tamper alarm are displayed with a
T
in front of the zone number.
To reset a zone in alarm
1. Enter your PIN code.
2. Press
[OFF]
.
The display shows:
0- All 1, Area One 2, Area Two 3, Area three
Enter Area:
3. Enter the area number of the zone in alarm (flashing LED) and press
[ENTER]
.
The display shows:
There are no alarms in this area
Code:
4. Determine where the alarm occurred by reviewing the quick alarm history (page
5. Fix the problem.
Further information about alarms
•
If the alarm conditions are no longer valid, and the alarm has been reset, you must contact your
central station company to ensure that they take no further action.
•
If you are unable to reset an alarm because of a faulty zone, refer to the section Menu option 10,
Inhibit zone, page
•
You can only reset an alarm for an area that is assigned to your PIN code. If you are unable to
reset the alarm, ensure that the flashing area LED is for an area you can disarm with your PIN
code. If not, your attempt to reset the alarm will result in arming/disarming your system.
•
If you are unable to reset a system alarm because the conditions require the service technician to
attend, refer to the section on Inhibit/Uninhibit RAS/DGP (Menu option 16 on page
•
The system can be programmed in such a way that certain alarms (like tamper alarms) require a
specific action from your installer. "Engineer reset req" will appear in the display and a code will