![GE Advent Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/ge/advent/advent_installation-instructions-manual_132114089.webp)
87
Advent Commercial Fire System
Appendix B: Reference Tables
This appendix contains tables for selecting zone type num-
bers, system features, X10 Module house, unit codes and
responses, SuperBus device unique ID numbers, and text
descriptor numbers. Table notes (if any) appear at the bot-
tom of the last page of the table.
Note
Fire zone types are always active.
Table B.1 Zone Type Characteristics
No.
Name
Application
Ac
tiv
e
Le
v
e
l
Al
a
rm
/Si
re
n
De
la
y
Supe
rv
iso
ry
Re
s
tora
l
CS Ala
rm
Re
po
rt
C
S
Canc
el Re
port
B
y
p
a
s
sab
le
Chim
e
R
e
set
s A
c
ti
vity
T
im
e
r
00
Fixed Panic 24-hour audible fixed emergency
buttons.
1, 2, 3, 4, 5 Police/Police
Instant
√
√
√
√
01
Portable
Panic
24-hour audible portable
emergency buttons.
1, 2, 3, 4, 5 Police/Police
Instant
√
√
√
02
Fixed Panic 24-hour silent fixed emergency
buttons.
1, 2, 3, 4, 5 Police/Silent
Instant
√
√
√
√
03
Portable
Panic
24-hour silent portable emergency
buttons.
1, 2, 3, 4, 5 Police/Silent
Instant
√
√
√
04
Fixed
Auxiliary
24-hour auxiliary sensor, such as
Pendant Panic or holdup button.
1, 2, 3, 4, 5 Aux./Aux.
Instant
√
√
√
√
05
Fixed
Auxiliary
24-hour auxiliary emergency
buttons. Siren shut-off confirms
CS alarm report.
1, 2, 3, 4, 5 Aux./Aux.
Instant
√
√
√
√
06
Portable
Auxiliary
24-hour portable auxiliary alert
buttons.
1, 2, 3, 4, 5 Aux./Aux.
Instant
√
√
√
07
Portable
Auxiliary
24-hour portable auxiliary button.
Siren shut-off confirms CS alarm
report.
1, 2, 3, 4, 5 Aux./Aux.
Instant
√
√
√
08
Special
Intrusion
Special belongings, such as gun
cabinets and wall safes.
1, 2, 3, 4, 5 Police/Police
Instant
√
√
√
√
√
09
Special
Intrusion
Special belongings, such as gun
cabinets and wall safes.
1, 2, 3, 4, 5 Police/Police
Standard
√
√
√
√
√
10
Entry/Exit
Delay
Entry and exit doors that require a
standard delay time.
2, 3, 4, 5
Police/Police
Standard
√
√
√
√
√
√
√
11
Entry/Exit
Delay
Garage doors and entrances that
require an extended delay time. *
2, 3, 4, 5
Police/Police
Extended
√
√
√
√
√
√
12
Entry/Exit
Delay
Driveway gates and entrances that
require a twice extended delay
time. *
2, 3, 4, 5
Police/Police
Twice
Extended
√
√
√
√
√
√
13
Instant
Perimeter
Exterior doors and windows.
2, 3, 4, 5
Police/Police
Instant
√
√
√
√
√
√
√
14
Instant
Interior
Interior doors.
2, 3, 4, 5
Police/Police
Follower
√
√
√
√
√
√
15
Instant
Interior
Interior PIR motion sensors. *
2, 3, 4, 5
Police/Police
Follower
√
√
√
√
√
16
Instant
Interior
Interior doors.
3, 4, 5
Police/Police
Follower
√
√
√
√
√
√
17
Instant
Interior
PIR motion sensors. *
3, 4, 5
Police/Police
Follower
√
√
√
√
√
18
Cross Zone
Instant
Interior
PIR motion sensors subject to false
alarms. * †
3, 4, 5
Police/Police
Follower
√
√
√
√
√
19
Delayed
Interior
Interior doors that initiate a delay
before going into alarm.*
3, 4, 5
Police/Police
Standard
√
√
√
√
√
√