Testing the reader
23
c.
Present a card to the reader. Observe that the reader
behaves as described in the section
d. Observe that the green LED turns on, indicating a
valid access has been granted by the host.
e.
Open the door. This verifies that the reader strike
relay operates properly.
Indicators
A tri-color LED (red, yellow, and green), and a beeper are
incorporated into the reader and operate as indicated in the
following table:
Table 2.
Indicators
Condition
Standard indicators
Power-on Self Test Red LED flashes, Yellow LED flashes, Green LED
flashes
Reader Ready
Yellow LED on continuously
Badge Read
Yellow LED flashes briefly, 1 short beep
Valid Access
Green LED on until door strike is deactivated
Loss of
Communication
(Supervised)
Red LED flashes slowly, every 2 seconds, 3 short
beeps every 30 seconds
Tamper
(Supervised mode)
Red LED flashes quickly (every 400 ms), 3 short beeps
every 30 seconds
Alarm State
Red LED may be turned on and off and the beeper
may be sounded by the microcontroller, to indicate
an alarm state. Consult the appropriate Access
Control manual for details on this operation.
Содержание 940
Страница 14: ...Model 940 Reader Installation Manual 10 Figure 3 Model 940 reader Gang box mounting...
Страница 15: ...Mounting the reader 11 Figure 4 Model 940 reader Direct wall mounting...
Страница 20: ...Model 940 Reader Installation Manual 16 Figure 6 Supervised F 2F wiring diagram...
Страница 22: ...Model 940 Reader Installation Manual 18 Figure 7 Unsupervised F 2F wiring diagram...
Страница 24: ...Model 940 Reader Installation Manual 20 Figure 8 Wiegand wiring diagram...
Страница 32: ...Model 940 Reader Installation Manual 28 Notes...
Страница 33: ...Regulatory approvals 29 Notes...
Страница 34: ...Model 940 Reader Installation Manual 30 Notes...