background image

Wall

Must be
flat

Must be
flat

Must be
level

Must be level

30”

smooth cut

9/16”

9/16”

25”

ALTERNATE CONSTRUCTION PREPARATION

Refer to the Filler or Backguard Kit instructions
for Installation details.

OPTIONAL MAINTOP FILLER OR
BACKGUARD KIT

If counter opening extends to the wall, it will
require Maintop Filler Kit (JXS66XX) or
Backguard Kit (JXS32XX) to close the gap. 

NOTE:

If the countertop is greater than 25”, 

it will show a gap between the backguard 
and wall or between filler kit and the wall.

If the countertop is less than 25”, a gap will
occur between the countertop front and the
control panel ends. 

(See page 10, Step 3).

A

ISLAND INSTALLATION

When installing in an island or other 
non-standard location, countertop cutout 
dimensions must be according to page 5.

For the anti-tip bracket instructions, see 
page 9.

In this application, do not use Backguard Kit
(JXS32XX).

B

CABINETS OVER THE RANGE 
LESS THAN 30”

If a 30” clearance between cooking surface 
and overhead combustible material or metal
cabinets cannot be maintained, protect the 
underside of the cabinets above the cooktop
with not less than 1/4” insulating millboard
covered with sheet metal not less than 0.0122”
thick.

C

CABINET CUTOUT HEIGHT
MORE THAN 27-1/2” USE
LOWER TRIM KIT

Optional Lower Trim to fill space beneath 
27-1/2” min. requirement (see page 4). 
Use lower Trim Kit JXS96XX.

D

14

Installation Instructions

Содержание 131-10595-2 1-07 JR

Страница 1: ...appliance must be properly grounded ATTENTION INSTALLER All electric drop in ranges must be hard wired direct wired into an approved junction box A plug and receptacle is NOT permitted on these produ...

Страница 2: ...d hookup of your range connected by a qualified electrician After installation have the electrician show you where your main range disconnect is located Check with your local utilities for electrical...

Страница 3: ...he kitchen floor Flatten and place a piece of the shipping carton in front of the installation location to protect the flooring Inspect Installation Location Inspect cutout dimensions and location of...

Страница 4: ...ts for 0 spacing from vertical walls below countertops Allow 1 4 minimum clearance at the back wall above the countertop Wall coverings counters and cabinets around range must withstand heat up to 200...

Страница 5: ...nd mark with a straight edge Using a straight edge mark the back line at 23 3 16 from the front edge of the counter Be careful not to damage the adjacent cabinets while cutting the countertop Remove c...

Страница 6: ...ion box Feed wires and conduit through the open hole and snap the conduit fitting into the hole Route the conduit in a manner that will not interfere with the rear wire cover The conduit must be route...

Страница 7: ...using wire nuts Attach the appliance grounding lead green or bare copper in accordance with local codes If the residence grounding conductor is aluminum see WARNING note see page 6 Connect the oven re...

Страница 8: ...obtained NOTE TO ELECTRICIAN The 3 power leads supplied with this appliance are UL recognized for connection to larger gauge household wiring The insulation of these 3 leads is rated at temperatures...

Страница 9: ...Counter 2 For 1 18 3 cm Counter 3 For 1 5 Counter 4 For 3 5 5 Alternate shown below Anti tip bracket location rear of range Cooktop ANTI TIP INSTALLATION ALTERNATE ANTI TIP INSTALLATION Interior wall...

Страница 10: ...OPENING It is suggested that two people lift the range into place carefully setting the side metal flanges on the edges of the countertop opening Carefully slide the range toward the back of the openi...

Страница 11: ...notch on the sides of the range and not touch the top of the notch when the range is fully seated on the countertop If the screws do not meet the requirements move the screws to a position that meets...

Страница 12: ...e of slot Hinge arm Hinge notch Notch of hinge securely fitted into bottom of hinge slot Hinge in locked position REPLACING THE OVEN DOOR NOTE The oven door is heavy You may need help lifting the door...

Страница 13: ...echeck the range wiring connections If change is made to connections retest again If no change is required have building wiring checked for proper connections and voltage It is recommended that the cl...

Страница 14: ...ontrol panel ends See page 10 Step 3 A ISLAND INSTALLATION When installing in an island or other non standard location countertop cutout dimensions must be according to page 5 For the anti tip bracket...

Страница 15: ...15 Notes...

Страница 16: ...Printed in the United States 16 Notes...