Wall
Must be
flat
Must be
flat
Must be
level
Must be level
30”
smooth cut
9/16”
9/16”
25”
ALTERNATE CONSTRUCTION PREPARATION
Refer to the Filler or Backguard Kit instructions
for Installation details.
OPTIONAL MAINTOP FILLER OR
BACKGUARD KIT
If counter opening extends to the wall, it will
require Maintop Filler Kit (JXS66XX) or
Backguard Kit (JXS32XX) to close the gap.
NOTE:
If the countertop is greater than 25”,
it will show a gap between the backguard
and wall or between filler kit and the wall.
If the countertop is less than 25”, a gap will
occur between the countertop front and the
control panel ends.
(See page 10, Step 3).
A
ISLAND INSTALLATION
When installing in an island or other
non-standard location, countertop cutout
dimensions must be according to page 5.
For the anti-tip bracket instructions, see
page 9.
In this application, do not use Backguard Kit
(JXS32XX).
B
CABINETS OVER THE RANGE
LESS THAN 30”
If a 30” clearance between cooking surface
and overhead combustible material or metal
cabinets cannot be maintained, protect the
underside of the cabinets above the cooktop
with not less than 1/4” insulating millboard
covered with sheet metal not less than 0.0122”
thick.
C
CABINET CUTOUT HEIGHT
MORE THAN 27-1/2” USE
LOWER TRIM KIT
Optional Lower Trim to fill space beneath
27-1/2” min. requirement (see page 4).
Use lower Trim Kit JXS96XX.
D
14
Installation Instructions