CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.28
2.5.2.3
Bypass
To temporarily remove a zone from operation when arming the system.
A menu entry that groups bypass options.
2.5.2.3.1
Auto Bypass
A menu option that automatically bypasses interior follower zones if no exit is
detected during the exit delay time. The exit is detected by the opening and
closing of an entry/exit zone.
2.5.2.3.2
Code Required
A menu option that specifies whether a user code is required for bypassing
zones.
2.5.2.3.3
Sounder Alert
A menu option that activates the keypad buzzer when a user arms the system
with one or more zones bypassed.
2.5.2.3.4
Bypass Toggle
A menu option that allows an interior zone be bypassed or included while the
system is armed.
2.5.2.4.1
Mains/Batt Sounder Alert
A menu option that causes the keypad sounder to beep upon arming or
disarming if the mains power is missing or a low battery is detected.
2.5.2.4.2
Zone Lost Gives Tamper
A menu option that sends a report to the central station when a wireless zone
sensor is lost and activates a tamper alarm. Different reports are sent
depending on the system status. When armed the tamper and the lost report
are sent. When disarmed only the lost report is sent.
2.6
System Settings
A menu entry that groups programmable system features and reporting
options.
2.6.1
Timers
A menu entry that groups timer options.
2.6.1.1
Inputs
A menu entry that groups time settings relating to inputs.
2.6.1.1.1
Fire Verification Time
A menu option that sets the amount of time within which a second trip must
occur on a smoke detector in order to generate an alarm.
2.6.1.1.2
Zone Inact. Unit
A menu option that allows the zone inactivity option to be configured in hours
or days.
2.6.1.1.3
Zone Inactivity Monitor
A menu option that sets the zone inactivity time. It is possible to specify this
time in minutes or hours.
2.6.1.1.4
Double Knock Time
A menu option that sets the double knock time. If a double knock zone is
opened twice within this time, an alarm is activated.
2.6.1.1.5
Double Knock Open Time
A menu option that sets the double knock open time. If a double knock zone
remains open longer than this time, an alarm is activated.
2.6.1.1.6
B-Alarm Timer
A menu option that sets the time during which a second B-Alarm Trip event is
treated as a full burglary alarm.
2.6.1.2
Power
A menu entry that groups the timer options relating to power events.
2.6.1.2.1
Batt Dynamic Test Duration
A menu option that sets the length of time that the control panel performs the
Dynamic Battery test. This can be between 0 to 255 minutes where 0 is no
test.
2.6.1.2.2
Mains Report Delay
A menu option that sets the length of time between detecting a mains failure
on the control panel and sending a report to the central station. The restore
event is sent four minutes after the mains is restored.
2.6.1.2.3
Power Up Delay
A menu option that sets the time between mains restore after a power failure
and the system powering up again. This can be set from 0-60 seconds. 0
means no power up delay.
2.6.1.3
Sounders
A menu entry that groups timers for the internal siren, external siren and chime
duration on the keypad.
Location
Term
Definition