CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.15.10
15.4.1
Site Initiated
A menu option that allows an upload/download session between the module
and the PC to be initiated from a keypad.
15.4.2
Remote Initiated
A menu option that allows an upload/download session between the module
and the PC to be initiated by the PC. The PC dials into the module. You must
dial the data phone number to dial into the GSM for upload/download.
It is advisable to enable this setting only for a private network using a firewall.
15.4.3
Auto U/D at Test Time
A menu option that configures the module to automatically dial the PC to
initiate an upload/download session after an autotest. You must program the
autotest on the control panel.
15.4.4
IP Address
A menu option that configures the address of the PC running upload/download
software.
15.5
Automation
A menu entry that groups automation options.
15.5.1
Enable Automation
A menu option that allows automation systems to control the system via the
CS7050 TCP/IP module.
15.5.2
IP Address
A menu option that configures the address of the PC running automation
software.
15.6
Event Recorder
A menu entry that groups event recorder options.
15.6.1
Send Tags to Recorder
This option is not used in Europe.
15.6.2
IP Address
A menu option that configures the address of the selected event recorder.
15.7.1
Reporting
A menu entry that groups TCP/IP reporting options.
15.7.1.1
Report Format
A menu option that configures the communicator format used to report to TCP/
IP receivers. Consult the instructions for your central station receiver to
determine which format is compatible.
15.7.1.2
Control Panel is Backup
A menu option. This allows the control panel to act as a backup to the CS7050.
This means that when the CS7050 fails to send a report, it sends an expansion
event to the control panel and the control panel sends the report instead.
15.7.1.3
Receiver 2 as Backup
A menu option that configures the module to send backup reports to its second
TCP/IP receiver.
15.7.1.4
Receiver Polling
A menu option that configures the module to send polling messages to the
report receivers.
15.7.1.5
Polling Time
A menu option that configures the TCP/IP polling time. This value must match
the TCP/IP polling time set on a TCP/IP receiver. The value chosen is
determined by the level of security required and the cost of data transmission.
This can be from 1 to 255 seconds. If set to 0, the option is disabled.
15.7.2
Network
A menu entry that groups network options.
15.7.2.1
Use DHCP
A menu option that configures the CS7050 to use a dynamically assigned IP
address. If this option is enabled, you should configure a Polling Time. If this
option is disabled, configure Our E-mail Address, Gateway IP Address and
Subnet Mask.
15.7.2.2
Our IP Address
A menu option that configures the IP address assigned to the module.
15.7.2.3
Gateway IP Address
A menu option that configures the IP address of the gateway used by the
module. You must power down the CS7050 module and power it back up to
initialize the new IP address.
Location
Term
Definition