2.2 ORDER CODES
2 PRODUCT DESCRIPTION
2
2.2.2 REPLACEMENT MODULES
Replacement modules can be ordered separately. When ordering a replacement CPU module or faceplate, provide the
serial number of your existing unit.
Not all replacement modules may be applicable to the L60 relay. Only the modules specified in the order codes are
available as replacement modules.
Replacement module codes are subject to change without notice. See the ordering page at
http://www.gedigitalenergy.com/multilin/order.htm
for the latest L60 ordering options.
The replacement module order codes for the horizontal mount units are shown below.
76
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 1 Channel
77
IEEE C37.94, 820 nm, 64 kbps, multimode, LED, 2 Channels
7A
820 nm, multimode, LED, 1 Channel
7B
1300 nm, multimode, LED, 1 Channel
7C
1300 nm, single-mode, ELED, 1 Channel
7D
1300 nm, single-mode, Laser, 1 Channel
7E
Channel 1 - G.703; Channel 2 - 820 nm, multimode
7F
Channel 1 - G.703; Channel 2 - 1300 nm, multimode
7G
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode ELED
7H
820 nm, multimode, LED, 2 Channels
7I
1300 nm, multimode, LED, 2 Channels
7J
1300 nm, single-mode, ELED, 2 Channels
7K
1300 nm, single-mode, Laser, 2 Channels
7L
Channel 1 - RS422; Channel 2 - 820 nm, multimode, LED
7M
Channel 1 - RS422; Channel 2 - 1300 nm, multimode, LED
7N
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, ELED
7P
Channel 1 - RS422; Channel 2 - 1300 nm, single-mode, Laser
7Q
Channel 1 - G.703; Channel 2 - 1300 nm, single-mode Laser
7R
G.703, 1 Channel
7S
G.703, 2 Channels
7T
RS422, 1 Channel
7W
RS422, 2 Channels
Table 2–6: ORDER CODES FOR REPLACEMENT MODULES, HORIZONTAL UNITS
UR
-
**
-
*
POWER SUPPLY (redundant supply only available in
horizontal units and must be same type as main
supply)
|
SH
A
|
125 / 300 V AC/DC
|
RL
H
|
24 to 48 V (DC only)
CPU
|
T
|
RS485 with 3 100Base-FX Ethernet, multimode, SFP with LC
|
U
|
RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LC
|
V
|
RS485 with 3 100Base-T Ethernet, SFP with RJ-45
FACEPLATE/DISPLAY
|
3C
|
Horizontal faceplate with keypad and English display
|
3D
|
Horizontal faceplate with keypad and French display
|
3R
|
Horizontal faceplate with keypad and Russian display
|
3A
|
Horizontal faceplate with keypad and Chinese display
|
3P
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and English display
|
3G
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and French display
|
3S
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Russian display
|
3B
|
Horizontal faceplate with keypad, user-programmable pushbuttons, and Chinese display
|
3K
|
Enhanced front panel with English display
|
3M
|
Enhanced front panel with French display
|
3Q
|
Enhanced front panel with Russian display
|
3U
|
Enhanced front panel with Chinese display
|
3L
|
Enhanced front panel with English display and user-programmable pushbuttons
|
3N
|
Enhanced front panel with French display and user-programmable pushbuttons
|
3T
|
Enhanced front panel with Russian display and user-programmable pushbuttons
|
3V
|
Enhanced front panel with Chinese display and user-programmable pushbuttons
|
3I
|
Enhanced front panel with German display
|
3J
|
Enhanced front panel with German display and user-programmable pushbuttons
CONTACT INPUTS AND OUTPUTS
|
4A
|
4 Solid-State (no monitoring) MOSFET outputs
|
4B
|
4 Solid-State (voltage with optional current) MOSFET outputs
|
4C
|
4 Solid-State (current with optional voltage) MOSFET outputs
|
4D
|
16 contact inputs with Auto-Burnishing (maximum of three modules within a case)
|
4L
|
14 Form-A (no monitoring) Latching outputs
|
67
|
8 Form-A (no monitoring) outputs
|
6A
|
2 Form-A (voltage with optional current) and 2 Form-C outputs, 8 contact inputs
|
6B
|
2 Form-A (voltage with optional current) and 4 Form-C outputs, 4 contact inputs
|
6C
|
8 Form-C outputs
|
6D
|
16 contact inputs
|
6E
|
4 Form-C outputs, 8 contact inputs
|
6F
|
8 Fast Form-C outputs
|
6G
|
4 Form-A (voltage with optional current) outputs, 8 contact inputs
|
6H
|
6 Form-A (voltage with optional current) outputs, 4 contact inputs
|
6K
|
4 Form-C and 4 Fast Form-C outputs
|
6L
|
2 Form-A (current with optional voltage) and 2 Form-C outputs, 8 contact inputs
|
6M
|
2 Form-A (current with optional voltage) and 4 Form-C outputs, 4 contact inputs
|
6N
|
4 Form-A (current with optional voltage) outputs, 8 contact inputs
|
6P
|
6 Form-A (current with optional voltage) outputs, 4 contact inputs
|
6R
|
2 Form-A (no monitoring) and 2 Form-C outputs, 8 contact inputs
|
6S
|
2 Form-A (no monitoring) and 4 Form-C outputs, 4 contact inputs
|
6T
|
4 Form-A (no monitoring) outputs, 8 contact inputs
|
6U
|
6 Form-A (no monitoring) outputs, 4 contact inputs
|
6V
|
2 Form-A outputs, 1 Form-C output, 2 Form-A (no monitoring) latching outputs, 8 contact inputs
CT/VT MODULES
(NOT AVAILABLE FOR THE C30)
|
8L
|
Standard 4CT/4VT with enhanced diagnostics
|
8N
|
Standard 8CT with enhanced diagnostics
|
8M
|
Sensitive Ground 4CT/4VT with enhanced diagnostics
|
8R
|
Sensitive Ground 8CT with enhanced diagnostics
|
8P
|
4CT and 2 communications channels
INTER-RELAY COMMUNICATIONS
|
2A
|
C37.94SM, 1300 nm single-mode, ELED, 1 channel single-mode
|
2B
|
C37.94SM, 1300 nm single-mode, ELED, 2 channel single-mode
|
2E
|
Bi-phase, single channel
|
2F
|
Bi-phase, dual channel
|
2G
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 1 Channel
|
2H
|
IEEE C37.94, 820 nm, 128 kbps, multimode, LED, 2 Channels
|
2I
|
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1300 nm, single-mode, Laser
|
2J
|
Channel 1 - IEEE C37.94, multimode, 64/128 kbps; Channel 2 - 1550 nm, single-mode, Laser
Table 2–5: L60 ORDER CODES (REDUCED SIZE VERTICAL UNITS)
L60
-
*
**
- *
*
* - F
**
- H
**
- L
**
- N
**
- R
**
Reduced Size Vertical Mount
NOTE
NOTE
Содержание L60
Страница 10: ...x L60 Line Phase Comparison System GE Multilin TABLE OF CONTENTS ...
Страница 57: ...GE Multilin L60 Line Phase Comparison System 2 27 2 PRODUCT DESCRIPTION 2 3 SPECIFICATIONS 2 ...
Страница 58: ...2 28 L60 Line Phase Comparison System GE Multilin 2 3 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Страница 100: ...3 42 L60 Line Phase Comparison System GE Multilin 3 3 DIRECT INPUT AND OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 482: ...6 26 L60 Line Phase Comparison System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 554: ...10 8 L60 Line Phase Comparison System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Страница 674: ...B 110 L60 Line Phase Comparison System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 704: ...C 30 L60 Line Phase Comparison System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 720: ...E 10 L60 Line Phase Comparison System GE Multilin E 1 PROTOCOL APPENDIX E E ...
Страница 732: ...F 12 L60 Line Phase Comparison System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 742: ...H 8 L60 Line Phase Comparison System GE Multilin H 3 WARRANTY APPENDIX H H ...