imagination at work
IMMERSION
™
LED Refrigerated Display Lighting
Center Mullion LED Lights
750 mm
(30-inch): GELT403050CTR-SY/-SB (79777/79780), GELT403040CTR-SY/-SB (79783/79786)
900 mm
(36-inch): GELT403650CTR-SY/-SB (79795/79798), GELT403640CTR-SY/-SB (79801/79804)
Description Code (Single Unit Product Number / 10-Pack Product Number)
Vertical Cases
RV40 Series
GE
Lighting
Retrofit Installation Guide
BEFORE YOU BEGIN
Read these instructions completely and carefully.
A. Use this unit only in the manner intended by the manufacturer. If you
have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at the service panel
and follow appropriate lock out /tag out safety procedures.
Risk of electrical shock.
Disconnect power before servicing or installing product.
/
Risque de choc électrique.
Couper le courant avant de réparer ou installer le produit.
WARNING / AVERTISSMENT
Risk of injury.
While performing installations described, gloves, safety
glasses or goggles should be worn. /
Risque de blessure.
Lors de l'exécution
des installations décrites, des gants, des lunettes de sécurité ou des lunettes
de protection doivent être portées.
CAUTION / ATTENTION
PREPARE ELECTRICAL WIRING
Electrical Requirements
• The power supply must be supplied with 100-240 VAC,
50/60 Hz., and connected to an individual properly
grounded branch circuit, protected by a 15 or 20 ampere
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground and rated for 75°C (167°F).
• Do not overload driver, follow installation instructions
for the GEPS4000NCMUL-SY.
• Ensure that all connection points are sealed for damp
location using the appropriate method per the NEC or
local electrical code.
LED DRIVER COMPATIBILITY
This system is compatible with the
GEPS4000NCMUL-SY
LED Driver.
Please refer to the separate LED driver installation
guide for appropriate wiring connections.
FOR YOUR SAFETY
Read and observe all CAUTIONS and WARNINGS shown
throughout these instructions.
• Installation to be performed by factory trained service personnel only.
• For use inside a commercial refrigeration case with packaged foods only.
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequen-
cy energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-003. Ce DEFR de la classe
[A] est conforme à la NMB-003 du Canada.