ZXSF-1D

SF6 Leak Detector

Содержание ZXSF-1D

Страница 1: ...ZXSF 1D SF6 Leak Detector ...

Страница 2: ... Technical index 3 Ⅳ Appearance introduction 4 Ⅴ Features 4 1 Boot interface 4 2 Sensor calibration interface 5 3 Measurement interface 5 4 historical data 6 5 Save interface 9 6 System settings 10 Ⅵ Precautions 12 Ⅶ Packing List 13 Appendix Frequently Asked Questions 13 ...

Страница 3: ...stry SF6 low range such 0 50PPM there 0 3000PPM but the infrared SF6 sensor principle can customize these ranges 1 the principle of infrared absorption NDIR 2 dual wavelength with temperature compensation 3 high reliability with no cross reactivity to other gases 4 compared with electrochemical sensors sulfur hexafluoride sensor infrared sensor up to 10 years of life 5 cost effective affordable di...

Страница 4: ...on anti disturbance 10 High sensitivity good stability 11 Small beautiful easy to carry Ⅲ Technical index 1 Measuring range 0 999 9PPM 2 Accuracy 1PPM 0 50PPM inside 3 Resolution 0 1ppm 4 Repeatability 0 1PPM 5 Gas flow rate adjusted automatically 6 Probe protection stainless steel sintered filter 7 Operating voltage 110 220VAC AC and DC 8 Storage Temperature rating 25 70 9 Operating environment T...

Страница 5: ...uction The meter uses 4 3 TFT touch screen which is easy and convenient to use with more beautiful appearance The meter adopts 32 bit ARM MCU which provides higher response speed and better measuring precision Ⅴ Features 1 Boot interface The system guidance interface is as shown in the following picture ...

Страница 6: ...e system will automatically enter the sensor calibration interface 2 Sensor calibration interface The sensor calibration interface is as shown in the following picture After entering the sensor calibration interface you ll see such touch buttons as curve history save system and print After several minutes the system will automatically enter the measurement interface 3 Measurement interface ...

Страница 7: ...ata system setting and print data Meanwhile The curve interface is shown as follows After entering the measurement interface press measure to enter the curve interface You ll see the sample curves corresponding to SF6 content and current time At the time press measure to enter the measurement data interface 4 historical data 1 The history data interface is as shown in the following picture ...

Страница 8: ...lete Format Measure and print In this interface you ll see the information about the previous and next history data 2 Click Delete and the deleting prompt interface will be as shown in the following picture Click confirm and if the deletion is successful you ll enter the following interface ...

Страница 9: ...a interface 3 Click format and the formatting prompt interface will be as shown in the following picture Click confirm and if the formatting is successful you ll enter the following interface or click Return to return to the history data interface ...

Страница 10: ...ave interface is as shown in the following picture After entering the save interface you ll see such touch buttons as confirm measure and print Press confirm and the system will automatically save data for you If the data is successfully saved you ll enter the following interface ...

Страница 11: ...ing interface you ll see such touch buttons as help demarcate settings set time and measure In the system help interface there are some notes for the use of the meter Feel free to call us at the phone number indicated on the warranty card and use instructions if you are still not quite clear about any parts during your use of our product 2 Click demarcate and the meter will enter the system calibr...

Страница 12: ...for meter calibration and users are not recommended to use it 3 Click Settings and the meter will enter the setting interface Click the symbols of up down plus and minus on this interface to set the backlight intensity and standby time After the setting is completed click OK ...

Страница 13: ...g the battery in dangerous area is prohibited 3 Preventing collision extrusion and strenuous vibration during transportation or measurement process 4 Please charge the battery in time when the electricity indicator shows deficiency in the using process of the instrument It is only required to plug the socket into 220V power There is no need to open the power switch The battery will be charged auto...

Страница 14: ...7 Certificate Warranty Card 1 Appendix Frequently Asked Questions 1 How much time is needed for battery charging When there is need to charge battery When will the battery charging finish The charging time is different corresponding to the actual remaining electric quantity Generally speaking it is less than 12 hours Please charge the battery once the electricity quantity shows deficiency It is in...

Страница 15: ...ances when the gas route pollution is severe 3 The instrument is stagnated and the data is decreased in the measurement process what is the reason The sensor is implementing the function of gain regression In other words it will return to the previous measurement process for calibration At this time the interface data remains the same while the CPU is processing the data Therefore the date will de...