GASMAX II Operation & Maintenance Manual, Revision 7.0
Page 41
Figure 7-12: Technical Page Menu
SET BALANCE
adjusts the balance of a bridge-type sensor and must only be performed with ZERO gas on
the sensor. Balance is similar to a very coarse ZERO calibration and does not need to be precise since
subsequent calibrations will correct for small errors. ZERO gas applied to the sensor should provide a
Reading of
–
3 to +3 on the SENSOR BALANCE menu.
SET VOLTAGE
adjusts the excitation voltage applied to bridge type sensors and may vary from 2 to 6
volts. Local Smart Sensors automatically adjust the excitation voltage to match the needs of the sensor.
Remote sensors require manual adjustment. Excitation voltage must be measured
at the sensor
;
therefore, if the sensor is mounted some distance away from the GASMAX II, the excitation voltage may
have to be higher to compensate for losses in field wiring.
WARNING:
C I G ’ T
EXCITATION VOLTAGE MAY DAMAGE OR DESTROY THE
SENSOR.
S E N S OR B A L A N C E
R e a d i n g - 3
C o u n t s 4 9 6
U P / D N t o C h a n g e .
N E X T t o E x i t .
S E N S OR V OL T A GE
V o l t s 2 . 0 4
U P / D N t o C h a n g e .
N E X T t o E x i t .
WA R N I N G! H i g h v o l t a g e
ma y d a ma g e s e n s o r
* * * * * WA R N I N G* * * * *
P r e v i o u s C a l i b r a t i o n
w i l l b e e r a s e d .
E D I T t o c o n f i r m.
N E X T t o e x i t .
Ga i n = U n i t y
EDIT
EDIT
P GA S E T U P
Ga i n 2 5 . 0 %
C o u n t s 10 11
R e a d i n g 10 0
U p / D n t o C h a n g e .
N e x t t o e x i t .
S E L E C T I N P U T
C a t - B e a d ( 3 - Wi r e )
U P / D OWN t o c h a n g e
E D I T t o s e l e c t
N E X T t o e x i t
SENSOR BALANCE & SENSOR VOLTAGE
menus are only active when input type =
“Cat-Bead” 3-Wire”
S E L E C T E U N I T S
EDIT
% L E L
[ C u s t o m ]
S e t B a l a n c e
S e t S e n s o r V o l t a g e
S e t Ga i n t o U N I T Y
P r e A mp Ga i n S e t
I n p u t T y p e
Z E R O C a l V a l 0
>
>
>
>
>
T E C H N I C A L P A GE 2
R a w Mi n C n t s 5 11
R a w Ma x C n t s 10 0 0
Ma r k e r A c t i v e Y e s
Ma r k e r T X L E D N O
Ma r k L e v e l 3 . 0 mA
Ma r k A s * * ME S S A GE *