![GBC Explorer 107 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/gbc/explorer-107/explorer-107_operation-and-maintenance-manual_3934818076.webp)
Page 5 - 10
Explorer 107 Operation and Maintenance Manual
Operations
© GBC Pro - Tech December 1999
Reacting to an emergency
situation
a) In the event of an emergency, press an
E-STOP.
INFORMATION
W h e n a n E M E R G E N C Y S T O P i s e n g a g e d ,
all motion stops. The nip will not change
from the operating setting.
b) Resolve the emergency situation.
c) Reset the E-STOP by rotating 1/4 turn
clockwise. The E-STOP will unlatch.
!
S
T
O
P
E
M
E
R
G
E N C Y
Unlatch
INFORMATION
The Temperature control panel settings
are not affected when an E-STOP
has been pushed.
d) Ensure that the front safety shield is located
in the fully locked position.
INFORMATION
Power to the motor is removed when
the safety shield is not in the fully
locked position.
e) Press ON to resume running.
5.3 Set up
Initial set up of the Explorer 107 laminator is
easily attained when instructions are followed exactly.
It is suggested and helpful if you take the time to read
this section thoroughly before attempting to do any of
the steps.A complete understanding of this section will
enable you to follow the procedures descibed in
Section 6.1 Application.