Pocket Thermography Camera User Manual
11
4.2 Set Level & Span
You can adjust the temperature range with the Level & Span function. Set a temperature section
and the palette only works for targets within the temperature section. The Level & Span can be
manually or automatically adjusted to achieve a good thermal effect for better temperature
difference analysis.
Steps
1. Tap
Menu
, and select
.
2. Select auto adjustment
or manual adjustment
.
Auto Adjustment
Select
. The device adjusts temperature range parameters
automatically.
Manual Adjustment
There are 2 ways to manually adjust the range:
●
Adjust the temperature range based on selected area.
Tap an interest area of the screen. A circle is displayed around the
area, and the palette readjusts to the temperature range of the
area.
●
Adjust the maximum and minimum temperature of the range.
●
Tap to select the max. temperature, min. temperature, or both.
You can also tap the max. temperature or min. temperature at
the ends of the palette bar to select them.
●
Tap the arrows on the right side of the screen to adjust the
temperature value.
3. Press
Back
to exit.
4.3 Set Thermography Rule
You can set thermography rules to measure the min., max., and center temperatures of the
current scene.
Steps
1. Tap
Menu
, and select
.
2. Tap to select the thermography rule as required.
Hot
,
Cold
, and
Center
are selectable.
3. Tap
Back
to save and exit.
Note
●
The min., max., and center temperatures are displayed on the left top of the screen.
●
Tap the rule again to delete the rule.