CHAPTER 7: Managing the Storage Solution
www.gateway.com
86
Identifying drive members
You can quickly identify which drives in the enclosure are members of a specific
array.
On the Main screen, located on the right side of an array name, is an icon (Drive
Identify icon), that looks like an arrow pointing to the lower left corner. This is
used to turn on the identify function.
Clicking on the
Drive Identity
icon causes all drive members of that array in
the representation of the enclosure front view to have the
Drive Identity
(arrow) icon displayed on those drives. The icon also appears next to each logical
drive created from the drives of the array.
You can also identify specific drives in an array by flashing its Drive Status LED.
For more information, see
Rebuilding an array
Important
Only one rebuild can take place at a time.
If a rebuild is currently underway, the
second array scheduled for rebuild is
on-hold until the first array has
completed the rebuild.
This option is designed for situations where you want to manually start a rebuild
operation.
For example, if you inadvertently pulled the wrong drive from a working array
and that drive is now flagged as a failed drive. If you do not have a hot spare
defined, the array does not automatically begin a rebuild operation. You must
change the status of the flagged failed disk drive to a spare drive which clears
the condition and initiates a rebuild.
Содержание E-842R
Страница 1: ...USER GUIDE Gateway E 842R StorView Storage Management Application ...
Страница 2: ......
Страница 7: ...CHAPTER 1 1 Introduction Overview Inter server communication License manager ...
Страница 10: ...Chapter 1 Introduction www gateway com 4 ...
Страница 11: ...CHAPTER 2 5 Installation Setup for Microsoft Windows platforms Setup for Linux platforms ...
Страница 44: ...CHAPTER 3 Getting Started www gateway com 38 ...
Страница 76: ...CHAPTER 5 SAN LUN Mapping www gateway com 70 ...
Страница 77: ...CHAPTER 6 71 ControllerInformation Controller environmentals Controller advanced settings ...
Страница 86: ...CHAPTER 6 Controller Information www gateway com 80 ...
Страница 104: ...CHAPTER 7 Managing the Storage Solution www gateway com 98 ...
Страница 110: ...CHAPTER 8 Failover Performance and Additional Functions www gateway com 104 ...
Страница 120: ...APPENDIX A Troubleshooting and Support www gateway com 114 ...
Страница 144: ...APPENDIX B Event Logs www gateway com 138 ...
Страница 152: ...APPENDIX C Statistics www gateway com 146 ...
Страница 158: ...APPENDIX D Optimizing RAID 5 Write Performance www gateway com 152 ...
Страница 162: ...Index www gateway com 156 ...
Страница 163: ......
Страница 164: ...A MAN E 842R SW USR GDE R0 09 06 ...