14
Trouble Shooting Guide
All equipment is tested for proper performance before it is shipped from the factory. However, if you should
experience any difficulties, we recommend you check the guide below to help restore equipment to proper
operating standards before contacting Gates customer service.
Problem
Solution
Crimper will not come up to pressure.
●
Check the oil level in pump.
●
Check operation of pump relief valve. (See pump operation manual.)
Crimping leaves a “bell” or “tail” on ferrule.
●
Check location of ferrule in die fingers before crimping.
Crimping gives wrong crimp diameter.
●
Check for proper die set.
●
Check for proper hose/ferrule/stem combination.
●
Check for proper digital readout setting.
●
Check calibration of crimper.
●
Change digital readout setting until an acceptable crimp diameter
is obtained. (See page 9) Record new setting for future use.
NOTE: Published settings are only approximate values. You need
to adjust your setting so that the correct crimp diameter is achieved.
Pump will not activate crimper.
●
Check crimp switch on switchbox.
●
Check electrical connections between pump and crimper and
between pump and wall outlet.
Crimping unit is off center under the ram.
●
Make certain die backup ring is completely back against both rear
locating pins.
No digital readout, but crimper is
●
Check wiring harness to see if it is connected between switchbox
operational.
and digital readout. If connected properly, the digital readout
is faulty and must be replaced.
Содержание Power Crimp 707