background image

REVISION 2019-2

KG

Use and installation of the product 
must comply with Machinery 
Directive 2006/42/CE.

Verify that the system is EN 124445 
and EN 12453 standard compliant. 
Installation must be carried out by 
qualified personnel who are aware of 
the associated potential hazards, and 
are operating in full compliance with 
current regulations.

General safety precautions

This manual contains important information for the safety of consumers.
An improper installation can result in serious injury to people and/or property.
Before beginning the installation it is absolutely necessary to read this manual in its entirety.
Save this manual for future consultation.

GateMotors: +44 (0)1202 744958 • Technical support: +44 (0)1202 725489
www.gatemotors.co.uk • Sales and Accessories: +44 (0)1202 717191

The myAster motor is designed to automate swing gates. The use 
of this product for purposes other than those described above 
and installation executed in a manner other than instructed in this 
technical manual are prohibited.

All myAster systems are irreversible, therefore an electric lock is 
not essential – but an electric lock is recommended for additional 
security, or for use in areas exposed to high-winds. The electric 
lock must be installed on the gate leaf that opens first and must 
be connected with the terminals of the control unit.

If fitting an electric lock, remove all manual locks and bolts.

In the event of a power cut the gate motor can be released by 
manual operation.

Use of the product must be restricted to its intended use. Any 
other use is to be considered dangerous and therefore forbidden.

Do not allow children to play with the fixed command devices, or 
in the gate’s area of operation. Keep any remote control devices 
(i.e. transmitters) away from children.

Keep the gate and the gate opener regularly maintained. Use only 
myGate or GateMotors supplied spare parts.

Users are strictly forbidden to carry out any changes on the gate 
motor.

GateMotors is not liable for any damage resulting from improper, 
wrongful or unreasonable use.

The use of this equipment must observe the safety standards in 
force in the country where it is installed, as well as the standards 
governing proper installation.

KG

KG

KG

KG

KG KG

KG

KG KG

KG

KG

KGKG

Any lawn watering devices 

must not wet the gate 

motor from the bottom up.

There is sufficient 

space for manual 

release.

The opening of the automated 

gate is not an entrapment 

hazard with regards to any 

surrounding fixed parts.

Intended use and application

PRE-INSTALLATION 

CHECKLIST

Verify that the technical features 

fit your installation needs.

The gate hinges are in 

good condition and 

are suitably lubricated. 

The gate leafs 

swing freely and are 

clear of obstruction

The gate has mechanical 

stops in both the open 

and closed positions.

Always cut off the power 

during the installation or 

maintenance of any parts.

The gates are NOT on 

either an upward  

or downward slope.

KG KG

KG

KG

KG

KG

KG

KG

KG

KG

Содержание MyGate myAster 3

Страница 1: ...VISION 2019 2 automationKitforswinggates myAster GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 ENGLISH Installation Manual...

Страница 2: ...move all manual locks and bolts In the event of a power cut the gate motor can be released by manual operation Use of the product must be restricted to its intended use Any other use is to be consider...

Страница 3: ...screw RECOMMENDED GATE LEAF FIXINGS not included GateMotors 44 0 1202 744958 Technical support 44 0 1202 725489 www gatemotors co uk Sales and Accessories 44 0 1202 717191 myAster dimensions 50 mm 11...

Страница 4: ...00 rpm 1400 rpm Leaf s maximum length 2000 mm 2000 mm 2500 mm 2750 mm 3000 mm 3500 mm 4000 mm Leaf s maximum weight 275 Kg 350 Kg 250 Kg 350 Kg 150 Kg 250 Kg 250 Kg Maximum opening 110 110 110 110 110...

Страница 5: ...mm Left motor Right motor INWARD FACING Check that the open position of the automated gate is not an entrapment hazard with regards to any surrounding buildings or fixed objects and there is sufficie...

Страница 6: ...m 140 mm 140 mm Minimum leaf length 1150 mm 1130 mm 1130 mm 1130 mm 1140 mm 1120 mm 1100 mm 1070 mm 1050 mm myAster 5 D 275 mm 250 mm 225 mm 200 mm 175 mm 150 mm 125 mm 100 mm 75 mm A 275 mm 300 mm 29...

Страница 7: ...ecreased by the same amount as the A measurement is increased For example If installing the myAster 3Ti measurement A increasing 20 mm now 170 mm means measurement B ideally decreases 20 mm now 130 mm...

Страница 8: ...ill return to its default settings Manual release NB Check the manual opening of the gate leaf before definitively fixing the bracket S3 to make sure the gate can open fully to your required angle To...

Страница 9: ...conduits for the electrical cables feed the motors control panel and accessories separately in order to prevent interferences that may result in bad operation Fit the power cable keeping a curve as s...

Страница 10: ...ent removal tampering of any labels attached to the product will invalidate the warranty Transferring the warranty to any other person The warranty is only applicable to the original purchaser Under n...

Страница 11: ...er operated doors Requirements EN 12445 Industrial commercial and garage doors and gates Safety in use of power operated doors Test methods EN60335 1 Safety of household and similar electrical applian...

Страница 12: ...make and model Serial number INSTALLER DETAILS Company name Installer Telephone number Signature Date COMMISIONER DETAILS Name Signature Date GateMotors 44 0 1202 744958 Technical support 44 0 1202 7...

Отзывы: