background image

                                                       

GM-820A-Dual        A/C SYSTEM MAINTENANCE CENTRE-DUAL   

15 

 

12-1) Exchange dry filter 

A.  The dry filter must be exchange when it reaches the life time. There will give a message. 

B.  If  not  exchange  the  dry-filter  timely,  it  will  not  be  able  to  run  the  recovery,  flushing  and  supplying 

functions. 

C.  Operations: 

C-1: Please check the ID of the dry-filter at the label. Which is the SN. 

C-2: Select Exchange dry-filter Function and press ENTER key. 

C-3: Input the ID. 

C-4: And then do step by step as the information. 

Note: Please attention the mounting direction of the dry-filter. 

12-2) Clean pipe of the unit 

A.  Through this function, it can effectively remove the oil mist and trace moisture in the internal pipeline of 

the equipment, and ensure that the system is clean and pollution-free. 

B.  After a period of use, such as 3months, it should be run this function. 

C.  Operations: 

C-1: Power on, select refrigerant type, then select Equipment Maintenance. 

C-2: Select Clean Pipe of The Unit function and press ENTER key. 

C-3:  Connect  the  hoses  and  couplers  well  to  the  coupling  side  of  the  equipment,  and  open  the 

couplers. 

C-4: And then press ENTER key to run. 

Warning: this function is performed according to the type of refrigerant.

 

12-3) Calibration of load cell (operate by professionals) 

A.  When the load cell is not precise, it needs to be calibrated. 

B.  You need input the password 1510 before use this function. 

C.  If do the calibration of main tank load cell, please prepare a 10~20kg weight. 

If do the calibration of oil bottle load cell, please prepare a 1-3kg weight. 

D.  Follow the prompts step by step. 

Note: if here have some programs, please check according to the messages.

 

12-4) Drain used oil 

A.  It can control the used oil drained manually. 

B.  Select Drain Used Oil function and press ENTER key. 

C.  Press and hold ENTER key to drain, and release the key to stop. 

12-5) Empty internal refrigerant 

A.  Through this function, the refrigerant in the equipment can be emptied. 

B.  It is necessary to use another refrigerant recovery equipment (say as MM). 

C.  Operations: 

Содержание GM-820A-Dual

Страница 1: ...GM 820A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 1 GM 820A Dual A C System Maintenance Centre R1234a R1234yf...

Страница 2: ...TIC is not responsible for device damage or problem due to the usage of any optional parts or consumables instead of GATMATIC original products or GATMATIC recognized products Declaration Other produc...

Страница 3: ...lternators and heating components etc to avoid harm E Wear protective clothing gloves and goggles F As automotive air conditioning pipe flushing the operator must be fully familiar with automotive air...

Страница 4: ...12 8 New oil adding 12 9 Recharging 13 10 Auto Mode 14 11 Database 14 12 Equipment Maintenance 14 12 1 Exchange dry filter 15 12 2 Clean pipe of the unit 15 12 3 Calibration of load cell operate by p...

Страница 5: ...nd pulse flushing functions which greatly improve the cleaning effect E Using large size glass tube with LED backlighting can effectively observe the entire cleaning process F Vertically installing th...

Страница 6: ...Automatic recovering recycling E Automatic manual used oil drain F Vacuum timing G Automatic manual new oil injection H Quantitative recharging I Each function can operate independently J Auto mode K...

Страница 7: ...1 Parts descriptions HP gauge Alarm LCD display Keys R134a HP port R1234yf HP port LP gauge Printer R134a LP port R1234yf LP port Window Power switch Power socket R134A Tank R1234YF Tank Used oil bot...

Страница 8: ...cale handle the suspended state As shown in the figure below B Connect the power supply and power on Please operation as following C Set the language select one and press ENTER C Set the units select...

Страница 9: ...lease read this user manual carefully before operating 3 Preparations before Run Flushing function A Check the refrigerant type of the automobile air conditioning and connect the right couplers to the...

Страница 10: ...ompts If the process is terminated artificially it will can t be into the main function and back to the last Interface D After completion enter the function interface Description Flushing Recovery Thi...

Страница 11: ...easily causes damages to the air conditioning and risk of accident D In order to achieve good flushing performance the flushing time should be more than 20 minutes General the cleaning time for single...

Страница 12: ...his function it will clean the water vapor out from the A C system B It should be more than 15 minutes Generally it needs 15 minutes at least for the air conditioning only with front wind and 20 minut...

Страница 13: ...d release the key to stop C 3 2 If set the filling amount press ENTER key after set and it will stop automatically 9 Recharging A Select the Recharging Function and press the ENTER key B Set the recha...

Страница 14: ...full automatically after setting the parameters B Before running must drain out the used oil entirely and fill enough new oil into the new bottle Pay attention to the oil type C Operations C 1 Select...

Страница 15: ...nt Maintenance C 2 Select Clean Pipe of The Unit function and press ENTER key C 3 Connect the hoses and couplers well to the coupling side of the equipment and open the couplers C 4 And then press ENT...

Страница 16: ...Operations C 1 Power on select refrigerant type then select Equipment Maintenance C 2 Select Vacuum System Pipeline function and press ENTER key C 3 Connect the hoses and couplers well to the coupling...

Страница 17: ...le can be extended Or when the machine appear the High pressure Alarm it need do it immediately C Operations C 1 Remove the rear refrigerant tank and place it aside Note do not remove any pipes C 2 Op...

Страница 18: ...resh refrigerant tank to the LP port of equipment Note it should connect to the liquid port of fresh refrigerant tank If has no liquid port please place the fresh refrigerant tank upside down B 4 Open...

Страница 19: ...status of the machine 15 2 Servicer info Here you can set and check the servicer and dealer information The way for setting Press and keys at same time into the setup state Use the and keys to select...

Страница 20: ...0A Dual A C SYSTEM MAINTENANCE CENTRE DUAL 20 16 Help Here you can check all of the help messages Declare We reserve the right to modify the contents of this document without prior notice to our custo...

Отзывы: