Gasolec G12 Скачать руководство пользователя страница 1

 

 

G12 Instruction Manual 

 

 

 

The Best in  

Growheating 

 

 
 

 
 
 
 

 

 
 

 
 

 

 

 
 

 
 

 
 

GAMECO (NSW) PTY LTD 
161 Parramatta Road 

AUBURN NSW 2144 
Phone:  02-96485856 

Email:  [email protected] 
 

GAMECO (Victoria) 
65A Chifley Drive 

PRESTON VIC 3072 
Phone:  03-94803633 

  
GAMECO QUEENSLAND 

17 Roy Street 
MILTON QLD 4064 

Phone:  07-33777999 
 

GAMECO NEW ZEALAND LTD 
9 Villa Street 

Masterton NZ 
Phone 06-3701683 

 

Содержание G12

Страница 1: ...amatta Road AUBURN NSW 2144 Phone 02 96485856 Email martynt gameco com au GAMECO Victoria 65A Chifley Drive PRESTON VIC 3072 Phone 03 94803633 GAMECO QUEENSLAND 17 Roy Street MILTON QLD 4064 Phone 07 33777999 GAMECO NEW ZEALAND LTD 9 Villa Street Masterton NZ Phone 06 3701683 ...

Страница 2: ...which has developed under normal installation use and service GAMECO GASOLEC assumes no responsibility for the costs of removal and installation of the product or other incidental costs which may arise as a result of any defects in materials or workmanship This is an overview of Gameco s sole warranty with respect to the products delivered hereunder No statement representation agreement or underst...

Страница 3: ...e should never be above or below a heater and positioned to minimise radiant heat affects TO BE INSTALLED ONLY BY AN AUTHORISED PERSON DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE DO NOT USE OR STORE FLAMMABLE MATERIALS NEAR THIS APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION ...

Страница 4: ...th stand alone thermostat control G12TSLP With 24AC 12v DC solenoid valve control For use with Natural Gas G12 TM NG With stand alone thermostat control Gas rating 45 Mj hr Gas Connection The gas connection is located on the gas control valve For ULPG 3 8 BSP male connection For natural gas BSP male connection The heater has a circular reflector with a diameter of 570mm Giving a circular heating p...

Страница 5: ...e that gas is present at the burner inlet and check that all gas connections are gas tight and there are no leaks Use a soapy water mixture or other approved leak check solution to ensure all fittings are sealed Any tell tale bubbles will mean the joint is not sealed undo the joint check the sealing faces and threads for damage Reseal and recheck for tightness Ensure the soap solution does not con...

Страница 6: ...onto the tip of the thermocouple After 5 10 seconds release the button and the pilot flame should remain alight After checking that the flame is stable refit and slide the pilot cover closed 4 Set the shed controller to the desired temperature 5 The controller will signal the solenoid valve on the heater to open and put gas to the heater The gas will ignite smoothly from the pilot flame the flame ...

Страница 7: ...rson once a year Trouble shooting 1 If the gas flame is soft and yellow refer to previous section on heater maintenance 2 If the pilot fails to light first check to see that gas is present at the inlet and is at the correct pressure 3 Check that the pilot orifice is clear clean or replace if blocked 4 If the pilot light does not remain lit after releasing the control button check that the pilot fl...

Страница 8: ... all gas pipe and gas hose connections for leaks with soap and water solution or other leak check solution See Installation section 1 NEVER check for leaks with an naked flame 5 Ventilation air and combustion air must not be obstructed 6 Do not adjust the height maintain or repair the heater while it is still hot 7 Never bypass any safety devices 8 Do not operate a heater if you suspect there are ...

Страница 9: ...Gameco G12 9 ...

Страница 10: ...Gameco G12 10 ...

Отзывы: