LEAK CHECK
WARNING!
A leak test must be performed annually and each
time a cylinder is hooked up or if a part of the gas
system is replaced.
WARNING!
Never use an open flame to check for gas leaks.
Be certain no sparks or open flames are in the area
while you check for leaks. Sparks or open flames
will result in a fire or explosion, damage to property,
serious bodily injury, or death.
Leak Testing
This must be done before initial use, annually and
whenever any components are replaced or serviced.
Do not smoke while performing this test, and remove all
sources of ignition. Turn burner control to the off position.
Turn gas supply valve on.
Spray or brush a solution of liquid soap and water
onto all joints and connections of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose
joint or have the part replaced with one recommended by
our service agent and have the appliance inspected by a
certified gas installer.
If the leak cannot be stopped,
immediately shut off gas
supply, disconnect it, and have the appliance inspected
by a certified gas installer or dealer. Do not use the fire pit
until the leak has been corrected.
4
Servicing Instructions
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
WARNING!
For storage and cylinder exchange, disconnect
the cylinder only. Do not disconnect hose from the
appliance.