Page 5-12
MDE-4334C Atlas Start-up and Service Manual · April 2008
Pump Programming
Configuring the 9800 Series
Setting the DIP Switches
DIP Switch Settings
Switch
Number
Switch Function
Settings for Existing and Model
9850K
Settings for Models 9840K,
9852K, 9853K
1
Product 1
ON for Diesel, OFF for Gasoline
ON for Diesel, OFF for
Gasoline
2
Product 2
ON for Diesel, OFF for Gasoline
ON for Diesel, OFF for
Gasoline
3
Not Used
N/A
N/A
4
Unit of Measure
N/A
ON for Liters, OFF for Gallons
5
Pulser Multiplier
ON for 9850 and 9850K, OFF for
9852/9853
N/A
6
Number of Probes
ON for two (2) probes, OFF for one
(1) probe
ON for two (2) probes, OFF for
one (1) probe
7
Pulser Adder
ON for 9840
ON for 9840K
8
ATC
ON for ATC ON, OFF for ATC OFF ON for ATC ON, OFF for ATC
OFF
Error Codes
When operating the pump/dispenser, the 9800 series unit shows a two-digit error transaction
code on the LCD display when transactions are terminated abnormally (that is, other than
turning the pump handle off).
The error codes are displayed for two seconds at the left of the LCD window, alternating with
a five-second display of the last sale amount. The display alternates between the two until a
new transaction begins. When an error occurs, note the error code and relay the information to
the system administrator.
Code
Condition
01
RAM Failure
02
ROM Failure
55
Power Failure
56
Pulser Error
57
Timed Out
58
Limit Cutoff
Transaction error codes are displayed only when the pump/dispenser is operating in the
Standalone mode. When the 9800 series unit is in the Online mode, connected to a CFN or
TopKAT, transaction error codes are transmitted back to the system with the completed
transaction data.