background image

MDE-4541 Atlas™ Motor Kit M06699KXXX Installation • February 2006

Page 1

Introduction

This document provides information on installing replacement motors in Atlas™ units, along 
with the requisite belts and pulleys. While installing the new motor, pumping unit pressures 
will also need to be set to ensure problem-free operation.

Atlas Motor Kits

Kit No.

Description

M06699K001 

Atlas Motor Kit, 1 HP, 60HZ, 1PH

M06699K002

Atlas Motor Kit, 1 HP, 50HZ, 1PH

Required Reading

Before installing a kit, the installer must read, understand, and follow:

• This manual
• NFPA 30A, The Automotive and Marine Service Station Code
• NFPA 70, The National Electric Code
• Applicable federal, state and local codes and regulations

Failure to do so may adversely affect the safe use and operation of the equipment.

Note: This kit must be installed by a Gasboy Authorized Service Contractor (ASC) to ensure 

warranty.

Required Equipment

• Voltmeter with clamp on amp probe
• General mechanics tools 

MDE-4541

Atlas

 Motor Kit M06699KXXX Installation

 February 2006 

 

Содержание Atlas M06699K Series

Страница 1: ...99K002 Atlas Motor Kit 1 HP 50HZ 1PH Required Reading Before installing a kit the installer must read understand and follow This manual NFPA 30A The Automotive and Marine Service Station Code NFPA 70...

Страница 2: ...99K001 Part Number Description Quantity per Kit R14213 32 Motor 1 HP 60 Hz 1 PH 1 R06711 52 V Belt 4L290 1 R18900 27 Pulley A Belt 2 50 PD 1 Atlas Motor Parts List for M06699K002 Part Number Descripti...

Страница 3: ...ual Read understand and follow this manual and any other labels or related materials supplied with this equipment If you do not understand a procedure call a Gasboy Authorized Service Contractor or ca...

Страница 4: ...handling equipment Do not place any equipment in mouth This area contains a chemical known to the State of California to cause cancer WARNING This area contains a chemical known to the State of Califo...

Страница 5: ...oving the Old Motor 1 Disconnect motor wires in the junction box Mark wires in junction box so that you can be sure of connecting the new motor correctly 2 Remove the belt 3 Disconnect motor conduit a...

Страница 6: ...te flange 6 Replace the rubber mounts cupped washers and washers and the shoulder bolts in the slots on the bottom of the deck plate and thread the shoulder bolts into the clinch nuts in the bottom fr...

Страница 7: ...r Adjust if necessary Refer to Figure 3 Figure 3 Atlas Pump Motor Select Switch Motor power select switch shown in low voltage setting 110 volt nominal Verifying Performance 1 Verify completion of the...

Страница 8: ...s Screw 2 If the amperage from the initial test is low turn the adjustment screw clockwise and increase the preload and thus the flowrate and motor load Note If the initial bypass voltage is below 205...