ANITA ©
MP00006EN_181206
63
E0015 X-Axis or Y-Axis motor
communication error (E0015)
One of motors of axis doesn´t communicate with bus
system CAN. You have to check the connection of both
motors.
E0016 Y-Axis motor communication
error (E0016)
Motor of axis Y doesn´t communicate with bus system
CAN. You have to check the connection of motor.
E0017 X-Axis motor communication
error (E0017)
Motor of axis X doesn´t communicate with bus system
CAN. You have to check the connection of motor.
E0018 Needle motor communication
error (E0018)
Motor of needle doesn´t communicate with bus system
CAN. You have to check the connection of motor and
converter.
E0019
TECO drive error. Please turn
off and turn on
machine.(E0019)
Motor of needle doesn´t communicate with bus system
CAN. You have to check the connection of motor and
converter.
E0020 Unsupported or corrupted
file! (E0020)
Reading of pattern is impossible because the pattern could
be harmed or the pattern has wrong format.
E0021 File "filename".gps doesn't
exist. (E0021)
The file you want to open doesn´t exist.
E0022
Sewing machine is probably
switched off.\n Switch on
machine. (E0022)
Machine is probably turned OFF (motors and control
system). Turn ON the machine by pressing key under the
table and restart the PC software.
E0023 UART ACK error (E0023)
Error in serial interface communication.
E0024 UART track error (E0024)
Error in memory of pattern.
E0040 Error - low air pressure
(E0040)
Low level of air pressure in air pressure input.
E0044 Needle changer is in wrong
position (E0044)
Error occurred during needle change process. Check needle
change mechanism.
E0045 Advanced unit
communication error (E0045)
Communication error between control board B and
advanced board B.
E0046 Needle drive voltage error
(E0046)
Needle motor inverter voltage error. Check power supply
voltage of needle motor inverter (200 – 250 V).
E0047 Presser foot homing error
(E0047)
Step motor of presser foot cannot find sensor. Check
connection of motor and sensor. Check mechanical impede
of motor motion. Check connection of step motor driver.
(only on machines GPS/H)
E0048 Catch thread homing error
(E0048)
Step motor of catch thread cannot find sensor. Check
connection of motor and sensor. Check mechanical impede
of motor motion. Check connection of step motor driver.
(only on machines GPS/H)
www.garudan.cz
Содержание GPS/G-10060
Страница 69: ......