Страница 2: ...IPS42 Internal Power Supply Installation and User Guide 11 09 Magnum IPS42 Internal Power Supply for Edge Switch Family ...

Страница 3: ...ernal Power Supply Installation and User Guide 11 09 Important The Magnum IPS42 Series Internal Power Supply for Edge Switches contains no user serviceable parts Attempted service by unauthorized personnel shall ...

Страница 4: ...42 Internal Power Supply Installation and User Guide 11 09 Federal Communications Commission Radio Frequency Interference Statement This equipment generates uses and can radiate frequency energy and if not ...

Страница 5: ...nternal Power Supply Installation and User Guide 11 09 Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like ...

Страница 6: ...IPS42 Internal Power Supply Installation and User Guide 11 09 Contacting GarrettCom Inc Please use the mailing address phone fax numbers and email address listed below ...

Страница 7: ...IPS42 Internal Power Supply Installation and User Guide 11 09 TABLE OF CONTENTS Page 1 0 SPECIFICATIONS 1 ...

Страница 8: ...IPS42 Internal Power Supply Installation and User Guide 11 09 4 2 When Calling for Assistance 24 4 3 Return Material Authorization RMA Procedure 25 4 4 Shipping and Packaging Information 26 ...

Страница 9: ...IPS42 Internal Power Supply Installation and User Guide 11 09 1 0 SPECIFICATIONS 1 1 Technical Specifications ...

Страница 10: ...IPS42 Internal Power Supply Installation and User Guide 11 09 AC Power Supply Model IPS42 AC AC Power Connector standard IEC 320 male recessed Power Input 100 250 VAC 47 to 63 Hz auto ranging ...

Страница 11: ...y Installation and User Guide 11 09 Cooling Method All IPS42 models feature convection cooling for temperature un controlled locations All models have closed cases to withstand dirt and use special thermal techniques to transfer ...

Страница 12: ... Power Supply Installation and User Guide 11 09 Agency Approvals and Standards Compliance UL Listed UL 60950 cUL CE Emissions meets FCC Part 15 Class A IEC 61850 EMC and Operating Conditions Class C Power Substations ...

Страница 13: ...ion and User Guide 11 09 1 2 Summary of models and descriptions for IPS42 Series IPS42 AC DC Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch Requires simultaneous ordering of an ES42 without external power ...

Страница 14: ...RC Internal Power Supply chassis for use with any ES42H or ES42P Series Edge Switch Requires simultaneous ordering of an ES42 without external power supply as a separate line item Rated 44 to 57 VDC Dual Source Power input via recessed terminal block UL Listed and Surge protected ...

Страница 15: ...al Power Supply chassis for use with any ES42H or ES42P Series Edge Switch Requires simultaneous ordering of an ES42 without external power supply as a separate line item Standard worldwide AC power input via standard IEC320 recessed male connector UL Listed and Surge protected ...

Страница 16: ...IPS42 Internal Power Supply Installation and User Guide 11 09 2 0 INTRODUCTION 2 1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this ...

Страница 17: ...1 09 Remove the Magnum IPS42 Series Internal Power Supply from the shipping container Be sure to keep the shipping container should you need to ship the unit at a later date In the event there are items missing or damaged contact your supplier If you need to ...

Страница 18: ...IPS42 Internal Power Supply Installation and User Guide 11 09 2 3 Features and Benefits 100 to 250V range 4KV surge protected AC DC models are rated at 100 250V with a maximum of 4KV surge ...

Страница 19: ...rnal Power Supply Installation and User Guide 11 09 3 0 INSTALLATION This section describes the installation of the Magnum IPS42 Internal Power Supply including location mounting power cord and media connections ...

Страница 20: ...9 Installation of the Magnum IPS42 Series of products is a simple procedure The installation location is dependent upon the physical layout of the Ethernet network and associated cabling Make sure the unit is installed in a location that is easily accessible to ...

Страница 21: ...rnal Power Supply Installation and User Guide 11 09 Note The metal brackets supplied hold the back of the IPS42 unit out from the panel or wall behind it creating a rear space of about inch or 1cm This allows air ...

Страница 22: ...IPS42 Internal Power Supply Installation and User Guide 11 09 ...

Страница 23: ...IPS42 Internal Power Supply Installation and User Guide 11 09 3 1 2 DIN Rail mounting option The Magnum IPS42 Power Supply ...

Страница 24: ...Supply Installation and User Guide 11 09 3 2 Power Cord Installation For IPS42 DC w Dual Source and AC DC models that do not have the power cord installed at the factory follow the procedures as described below For detailed ...

Страница 25: ...tallation and User Guide 11 09 Use the Power Cord installation kit items for Dual Source shown in Fig 3 2b to connect the power cord to the unit Note For Single Source models the kit will include a single opening power cord cover and ...

Страница 26: ...IPS42 Internal Power Supply Installation and User Guide 11 09 For Dual Source models positions A and B will be used ...

Страница 27: ...IPS42 Internal Power Supply Installation and User Guide 11 09 ...

Страница 28: ...IPS42 Internal Power Supply Installation and User Guide 11 09 3 3 Hardware operated Alarm Contact The two screw Alarm Contacts feature standard on Magnum IPS42 Series ...

Страница 29: ... Guide 11 09 1 Four position terminal block positions 1 2 as shown in Figure 4 4a 2 The Alarm Relay contact connected to the two terminals 1 2 is hardware operated 3 By default it is NC normally closed It will open if there is any loss of power to the ...

Страница 30: ...ply Installation and User Guide 11 09 4 1 Before Calling for Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also ...

Страница 31: ...tion and User Guide 11 09 4 Make sure that an AC power cord is properly attached to each Magnum IPS42 Series unit Be certain that the AC power cord is plugged into a functioning and appropriate electrical outlet Use the PWR LEDs to verify ...

Страница 32: ...ernal Power Supply Installation and User Guide 11 09 4 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete description of the problem including the following points ...

Страница 33: ... Supply Installation and User Guide 11 09 4 3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL ...

Страница 34: ...9 GarrettCom will carefully test and evaluate all returned products will repair products that are under warranty at no charge and will return the warranty repaired units to the sender with shipping charges prepaid see Warranty Information Appendix A for complete ...

Страница 35: ...IPS42 Internal Power Supply Installation and User Guide 11 09 CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit ...

Страница 36: ...y Installation and User Guide 11 09 APPENDIX A WARRANTY INFORMATION GarrettCom Inc warrants its products to be free from defects in materials and workmanship for a period of three 3 years from the date of shipment by GarrettCom ...