background image

 

www  GarrettCom  com

.

.

www  GarrettCom  com

.

.

 
 

 
 
 
 

Corporate Headquarters

 

 

 

GarrettCom, Inc.

 

47823 Westinghouse Dr. 
Fremont, CA  94539-7437 
Phone  (510) 438-9071 
Fax  (510) 438-9072 
Website:  

http://www.GarrettCom.com

 

 

Email:  

[email protected]

 

 

                            

 
 

 
 
 
 
 
 

 
 
 
 
 

 

 

 

 

Magnum 10KG 

 

Managed Switch 

with Timing

 

 

 
 
 

Hardware 

Installation and User Guide

Содержание Magnum 10KG

Страница 1: ...www GarrettCom com Magnum 10KG Managed Switch with Timing Hardware Installation and User Guide ...

Страница 2: ...d personnel may render all warranties null and void If problems are experienced with Magnum 10KG Switch products consult Section 6 Troubleshooting Copyright 2012 GarrettCom Inc All rights reserved No part of this publication may be reproduced without prior written permission from GarrettCom Inc Printed in the United States of America GarrettCom Inc reserves the right to change specifications perfo...

Страница 3: ...sur le matériel du Canada Cet appareil est Classe A Electrical Safety requirements 1 This product is to be installed Only in Restricted Access Areas Dedicated Equipment Rooms Electrical Closets or the like 2 All products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product 3 This product shall be provided with a maximum 10A DC Li...

Страница 4: ...r Input connection 23 3 5 Alarm Contacts for monitoring internal power and Software Traps 24 3 6 Connecting the Console Terminal to Magnum 10KG 26 3 6 1 RJ45 Console port Serial port pin assignments 26 4 0 OPERATION 27 4 1 Switching Functionality 27 4 2 Auto Cross MDIX and Auto negotiation for RJ 45 ports 28 4 3 Flow control IEEE 802 3x standard 29 4 4 Packet Prioritization 802 1p QOS 30 4 5 Frame...

Страница 5: ...in Slots A D 39 6 0 TROUBLESHOOTING 40 6 1 Before Calling for Assistance 40 6 2 When Calling for Assistance 41 6 3 Return Material Authorization RMA Procedure 41 6 4 Shipping and Packaging Information 42 APPENDIX A DC Power Input 43 APPENDIX B Removal Installation of the Hot Swap power supply 46 Revisions Rev A 07 12 Initial Release ...

Страница 6: ...rotocol IEEE 802 1w Rapid Spanning Tree protocol IEEE 802 1q VLAN Tagging IEEE 802 3x Flow Control IEEE 802 3ad Link Aggregation Trunking IEEE 802 1x Port based network access control IEEE 802 3af Power over Ethernet PoE IEEE 802 3at Power over Ethernet PoE IEEE 1588v2 Timing compliance IPv6 Compliance Maximum 10 Mbps Ethernet Segment Lengths Unshielded twisted pair 100 m 328 ft Shielded twisted p...

Страница 7: ...e 40 to 140 F 40 to 60 C for UL 60950 and Component Parts rating 40 to 185 F 40 to 85 C for IEC 60068 Type Test short term rating Storage Temperature 40 to 185 F 40 to 85 C Ambient Relative Humidity 5 to 95 non condensing Altitude 200 to 13 000 ft 60 to 4000m Conformal Coating humidity protection optional Request quote Alarm Relay Contacts Form C One NC hardware controllable One NC software contro...

Страница 8: ...tor RJ45 see details at Section 3 6 10KG Mounting Rack mounting standard method Unit supplied with rack mounting brackets for mounting in a 19 rack Agency Approvals and Standards Compliance ANSI UL 60950 1 Issued 2007 03 27 Ed 2 UL Standard for Safety for Information Technology Equipment Safety Part 1 General Requirements CSA C22 2 No 60950 1 Issued 2007 03 01 Ed 2 Standard for Safety for Informat...

Страница 9: ...designed specifically for the 10KG series Configure up to 24 ports in a mix of Gb and 100Mb Heavy duty case with thermal fins for maximum convection cooling efficiency in a rack mount setting 10KGR HSPLL TF Same as Model 10KG HSPLL TF except chassis is a Reverse Mount unit All signal and power cables are in the rear Hot Swap Power supply models wo Thermal Fins MODEL DESCRIPTION 10KG HSPHH Magnum 1...

Страница 10: ...ermal fins for maximum convection cooling efficiency in a rack mount setting 10KGR HH TF Same as Model 10KG HH TF except chassis is a Reverse Mount unit All signal and power cables are in the rear 10KG L TF Same as Model 10KG H TF except the integral power supply is L 24 48VDC 10KGR L TF Same as Model 10KG L TF except chassis is a Reverse Mount unit All signal and power cables are in the rear 10KG...

Страница 11: ...0KGR HH Same as Model 10KG HH except chassis is a Reverse Mount unit All signal and power cables are in the rear 10KG L Same as Model 10KG H except the integral power supply is L 24 48VDC 10KGR L Same as Model 10KG L except chassis is a Reverse Mount unit All signal and power cables are in the rear 10KG LL Same as Model 10KG HH except the integral power supplies are L 24 48VDC 10KGR LL Same as Mod...

Страница 12: ...odule s separately May be factory configured with a variety of fiber and copper port modules selected designed specifically for the 10KG series Configure up to 24 ports in a mix of Gb and 100Mb Heavy duty case with thermal fins for maximum convection cooling efficiency in a rack mount setting 10KGPR L TF Same as Model 10KGP L TF except chassis is a Reverse Mount unit All signal and power cables ar...

Страница 13: ...Gb SFP transceiver 1000Mb LX 1310nm wavelength 10km SFP LX25 Gb SFP transceiver 1000Mb LX 1310nm wavelength 25km SFP ZX40 Gb SFP transceiver 1000Mb ZX 1550nm wavelength 40km SFP ZX70 Gb SFP transceiver 1000Mb ZX 1550nm wavelength 70km 100Mb SFP transceiver options for module 10 2RJSFP SFP100P FXMM2 100FX fiber SFP transceiver multimode 2km SFP100P FXSM20 100FX fiber SFP transceiver singlemode 20km...

Страница 14: ... 10Mb ST fiber ports 10K2 MSC Module w two multimode SC fiber ports 10K2T MSC Module w two multimode SC fiber ports with 1588 timing 10K2 SSC Module w two singlemode SC fiber ports 10K2T SSC Module w two singlemode SC fiber ports with 1588 timing 10K2 SSCL Module w two long haul singlemode SC fiber ports 10K4 FXSFP Module w four open 100Mb SFP ports 100Mb SFP transceiver options for module 10K4 FX...

Страница 15: ...self healing ring CONFORM05 RMOD Conformal coating heavy duty silicone at 5 mil thickness for interior PCBs PS and modules for moisture protection CONFORM08 RMOD Conformal coating heavy duty silicone at 8 mil thickness for interior PCBs PS and modules for corrosion in paper mining and oil gas industries DUAL SRC L Provides two separate 24 48VDC power inputs the unit will operate from either or bot...

Страница 16: ...d contain 1 Magnum 10KG Managed Switch base unit configured with user selected port module options installed and factory loaded MNS 6K or MNS 6K SECURE software installed 1 Set of two metal 19 rack mounting brackets with screws to mount to 10KG case Remove the items from the shipping container Be sure to keep the shipping container should you need to re ship the unit at a later date In the event t...

Страница 17: ...The Magnum 10KG provides an advanced level of 1588v2 timing features and accuracy using integrated hardware and software Advanced timing is supported on 100Mb and Gb ports and is configurable on both fiber and copper port types The Magnum 10KG also offers configurable Dual Hot Swappable power supplies for redundancy and increased reliability Both high voltage AC DC and low voltage DC hot swappable...

Страница 18: ...ut MNS 6K see the Magnum MNS 6K Software User guide in pdf format a separate document normally accessible via your web browser at ftp ftp garrettcom com or FTP client program at ftp GarrettCom com using user m6kuser password m6kuser All MNS 6K software information and the documentation related to MNS 6K and MNS 6K SECURE software can be accessed at GarrettCom s FTP site Alternatively for the lates...

Страница 19: ...assic FX Small Form Factor SFF and Small Form Pluggable SFP connectors for fiber cable Relay Contacts for monitoring internal power and user defined software events Two Alarm Relay contacts monitor basic operations One is for hardware and will signal loss of power internally The other is software controlled and will signal user defined software events such as a security violation or a redundancy f...

Страница 20: ...TP 2004 for rings and meshes fastest fault recovery interoperability RSTP 2004 provides reliable fast recovery from a fault in a redundant LAN which may include Magnum switches and routers as well as other vendors industry standard RSTP products Redundant topologies may include rings dual rings and complex meshes S Ring and Link Loss Learn for economical high availability using ring topology S Rin...

Страница 21: ...ted in an enclosed or multiple rack assembly verify that the equipment has a reliable and uncompromised earthing path This section describes installation of the Magnum 10KG Switch as well as connection of the various Ethernet media types 3 1 Locating Magnum 10KG Switches For Rack mounting see Section 3 3 For DC power input data see Appendix A The rugged metal case of the Magnum 10KG will normally ...

Страница 22: ...alculations to find fiber cable distance information 3 2 1 Connecting Twisted Pair CAT3 CAT5 UTP or STP The RJ 45 ports of the Magnum 10KG can be connected to the following two media types 100BASE TX and 10BASE T CAT 5 cables should be used when making 100BASE TX connections When the ports are used as 10BASE T ports CAT 3 may be used In either case the maximum distance for unshielded twisted pair ...

Страница 23: ...shielded twisted pair cabling is 100 meters 328 ft The following procedure describes how to connect a 1000BASE T twisted pair segment to the RJ 45 port The procedure is the same for both unshielded and shielded twisted pair cables 1 1000BASE T connections require that all four pairs or wires be connected Insert either end of the cable with an RJ 45 plug into the RJ 45 connector of the port Note th...

Страница 24: ... its useful life Note Always use an ESD wrist strap while handling the SFP transceivers since the SFP modules are static sensitive devices Note The copper 1000BASE T SFP transceiver port supports 1000Mb only It is recommended to use a straight through RJ 45 4 twisted pair connection while connecting to any Server workstation While connecting with any Switch repeater or other device it is recommend...

Страница 25: ...face They have four rubber feet to provide stability without scratching finished surfaces 3 3 1 Rack mounting options Installation of the Magnum 10KG Switch in a 19 rack is a simple procedure The units are 1 5U 2 63 high for Thermal fin version and 1U 1 74 high for non Thermal fin version When properly installed the front mounted LED status indicators should be in plain view and easy to read Rack ...

Страница 26: ...Magnum 10KG Managed Switch Installation and User Guide 07 12 21 www GarrettCom com Fig 3 3a 10KG Front mount dimensions model without Thermal Fin cover model with Thermal Fin cover ...

Страница 27: ...Magnum 10KG Managed Switch Installation and User Guide 07 12 22 www GarrettCom com Fig 3 3b 10KG Reverse mount dimensions model without Thermal Fin cover model with Thermal Fin cover ...

Страница 28: ...55 watts with the unit loaded with 8 Gb ports 16 100Mb fiber ports The AC model consumes 30 watts typical with 32 fully loaded copper ports and 60 watts typical with 24 fully loaded fiber ports The fan cooling option is required with fully loaded fiber ports When connecting the Ethernet cabling there is no need to power down the unit Individual cable segments can be connected or disconnected witho...

Страница 29: ...ned software malfunction such as an SNMP Trap or a Software Security violation or an RSTP Fault causes the contact to open and thus triggers an alarm in the user s monitoring system The second NC Alarm Contact is held closed when there is power on the main board inside of the Switch This provides a Hardware Alarm labeled H W because the NC contacts will open when internal power is lost either from...

Страница 30: ...ction of the Magnum 10KG unit and are green in color as shown in the picture Alarm contact ratings resistive 220 VDC 0 27A 60W 250VAC 0 25A 62 5VA 30VDC 2A 60W Fig 3 5a Alarm Contacts 1 2 hardware controlled 3 4 software controlled Fig 3 5b PoE Alarm Contacts software controlled 1 NO normally open 2 Common 3 NC normally closed Pin 1 Pin 4 Pin 1 Pin 3 ...

Страница 31: ... on the computer end Note For a detailed description of Managed Network Software MNS 6K and Magnum 10KG Switch software configuration for Network Management please refer to Magnum 6K Software Manual available on GarrettCom s FTP site Also available on GarrettCom s website at http www garrettcom com techsupport sw_downloads htm 3 6 1 RJ45 Console port Serial port pin assignments RJ45 Console port c...

Страница 32: ...ll other ports in a Magnum 10KG but local traffic on a port will not consume any of the bandwidth on any other port The Magnum 10KG units are plug and play devices There is no software configuring necessary to be done for basic operation at installation or for maintenance There is an optional Half Full duplex mode and 10Mbps or 100Mbps selection for the switched ports which must be configured thro...

Страница 33: ...ly used application for the Managed Magnum 10KG Switch copper ports is to connect one of them using a fiber media converter to another Switch in the network backbone or to some other remote 100Mb device In this case it is desirable to operate the fiber link at 100Mb speed and at either half or full duplex mode depending on the capabilities of the remote device Standard commercially available Fast ...

Страница 34: ... data loss if a long burst of activity causes the switch to save frames until its buffer memory is full This is most likely to occur when data is moving from a 100Mb port to a 10 Mb port and the 10Mb port is unable to keep up It can also occur when multiple 100Mb ports are attempting to transmit to one 100Mb port and in other protracted heavy traffic situations Magnum 10KG Switches implement the 8...

Страница 35: ...or express impose minimal frame latency they will also permit bad frames to propagate out to the Ethernet segments connected The cut through technique permits collision fragment frames which are a result of late collisions to be forwarded which add to the network traffic Since there is no way to filter frames with a bad CRC the entire frame must be present in order for CRC to be calculated the res...

Страница 36: ...ZX70 See http www garrettcom com techsupport power_budget pdf for more information on Power budget calculations 5 0 MAGNUM 10KG MANAGED SWITCH PORT MODULES This chapter describes each Port Module including appearance functionality and status displays 5 1 10KG Modules An important feature of the Magnum 10KG is the use of Port Modules for flexible mixed media connectivity to RJ 45 copper and various...

Страница 37: ...ng LED designations L A Link Activity Off No Link established ON Link established BLINKING Link Activity F H Full Duplex Half Duplex for Copper ports ON Full Duplex OFF Half Duplex for Copper port LED panel Power Indicators Illuminated when power is supplied to the internal switch Link indicator Illuminated when Link is established to that port ...

Страница 38: ...o provide valid indications of operating conditions on that port Using the 10KG management software MNS 6K or MNS 6K SECURE the user may disable auto negotiation and fix the desired operation of each RJ 45 port The user may select 10Mb or 100Mb speed and full or half duplex mode per port as required See the Magnum MNS 6K Software Manual for additional info A module similar to Model 10K4 RJ45 is al...

Страница 39: ...oE 802 3at support on the four RJ45 ports provide 25 Watts per port output when used in conjunction with the 10KGP chassis There are two LEDs per RJ 45 port on the module one for Link Activity and one for F H Duplex For the 10K4 RJ45 LED designations see Section 5 1 1 A twisted pair cable must be connected into an RJ 45 port and the Link L A indicator for that port must be ON indicating there is a...

Страница 40: ...terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received A module similar to Model 10K4 MLC is also available with IEEE 1588v2 Timing Synchronization as Model 10K4T MLC 5 1 5 10K4 SLC 10K4 SLCL four Singlemode LC use in Slots E H The ...

Страница 41: ...et connectivity When installed in a Magnum 10KG Series Switch it supports fiber optic cable distances up to the IEEE standard 100Mbps distance limits i e typically 2km at full duplex and 412m at half duplex The cable end is a plug in connector with both fiber strands terminated in one housing that cannot be improperly inserted Each port has a Link Activity L A LED indicating proper connectivity Li...

Страница 42: ...ode ST Fiber ports This option utilizes a ST type twist lock fiber optic connection The 100Mb Multimode SC and ST ports typically support fiber optic cable distances up to the IEEE standard 100Mbps distance limits typically 2km at full duplex Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being rece...

Страница 43: ...00Mb Singlemode ST Fiber ports supporting distances up to 20km This module provides the same functions as the Multimode version see Section 5 1 7 for more details A module similar to Model 10K2 SSC is also available with IEEE 1588v2 Timing Synchronization as Model 10K2T SSC A module similar to Model 10K2 SST is also available with IEEE 1588v2 Timing Synchronization as Model 10K2T SST 5 1 9 10K4 FX...

Страница 44: ...on The 10Mb Multimode ST ports typically support fiber optic cable distances up to the IEEE standard 10Mbps distance limits typically 2km at full duplex Each port has a Link Activity L A LED indicating proper connectivity Link with the remote device when lit and blinking Activity indicating packets being received 5 1 11 10 2RJSFP Two Gigabit RJ 45 or Two SFP use in Slots A D Two combo dual media p...

Страница 45: ...installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various components of the network are interoperable 2 Check the cables and connectors to ensure that they have been properly connected and the cables wires have not been crimped or in some way impaired during installation About 90 of network downtime can...

Страница 46: ...3 Return Material Authorization RMA Procedure All returns for repair must be accompanied by a Return Material Authorization RMA number To obtain an RMA number please use this URL https rma garrettcom com rma rma_request_noaccount php to fill out the form Please have the following information readily available Name and phone number of your contact person Name of your company institution Your shippi...

Страница 47: ...pped in a bubble wrap plastic sheet or bag for shipping protection You may retain all connectors and this Installation Guide CAUTION Do not pack the unit in Styrofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container 3 GarrettCom is not responsible for yo...

Страница 48: ...at user may ground either PS1 Power Supply 1 Pin 1 Negative N Pin 2 Positive L Pin 3 Ground PS2 Power Supply 2 Pin 4 Ground Pin 5 Negative N Pin 6 Positive L Chassis Ground ground wire connection to the 10KG chassis 10 32 thread Power Consumption 55 watts typical fully loaded with 8 Gb ports 16 100Mb fiber ports L 24 48VDC Power Input nominal range 22 to 60VDC H AC DC Power Input nominal range 90 ...

Страница 49: ...ctrical generating plants etc The 24VDC applications are mainly in heavy duty industrial automation such as factory floor mining process control plants HVAC COTS military equipment etc A3 0 10KG 24 48VDC 90 250VDC INSTALLATION This section describes the proper connection of the 24 48VDC leads to the DC power terminal block on the Magnum 10KG Switch The DC terminal block on the Magnum 10KG Managed ...

Страница 50: ...m 14AWG cable for connection to an earth wiring 2 Use only with Listed 10A circuit breaker provided in building installation 3 Complies with FDA radiation performance standards 21 CFR subchapter J or equivalent 4 Fastening torque of the lugs on the terminal block 9 inch pound max 5 To secure a centralized DC Power Source cable use at least four cable ties to secure the cable to the rack at least 4...

Страница 51: ...upply Tools Required 1 1 Phillips head screwdriver Step 1 Locate the Hot Swap power supply locking screw Loosen the locking screw until no longer engaged Step 2 Lift the Hot Swap power supply handle shown above to disengage from the 10KG chassis Step 3 Slide out the power supply from the chassis For installation reverse the order PS1 PS2 ...

Отзывы: