DV1KT3

108751

DV2KT3

108752

307402 01

Time switch

EN

1.  Basic safety information

Danger of death through electric shock or fire!

¾

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

 

The device is designed for installation on DIN top hat 
rails (in accordance with EN 60715)

 

The device corresponds to type 1 STU in accordance with 
IEC/EN 60730-2-7

 

Power reserve (10 years) is reduced if memory card is 
inserted (using battery power)

2.  Proper use

 

The time switch is used for lighting, ventilation and 

flushing applications etc.

 

Only for use in closed, dry rooms

 

!

Do not use on safety devices, e.g. escape route doors, fire 
safety equipment etc.

Disposal

¾

†

Dispose of device in environmentally sound manner

3.  Installation and connection

Mounting the time switch

Danger of death through electric shock or fire!

¾

¾

Installation should only be carried out by a 

qualified electrician!

WARNING

clic

Test tap

45° cable

Plug-in screwless 

terminal NC 

contact

Bluetooth 

G-OB BT 

(108755)

DuoFix plug-in 

terminal

 

!

Check the depth of the control cabinet when G-OB BT is 

connected. The depth must be > 94 mm.

¾

†

Mount on DIN top hat rails (as defined in EN 60715)

¾

†

Switched voltage-free

¾

†

Ensure device cannot be switched on

¾

†

Check absence of voltage

¾

†

Earth and bypass

¾

†

Cover or shield any adjacent live components

Connecting the cable

Wiring diagrams 108751 / 108752

C1

1 2 3

L N

N

L

L

C2

C1

1 2 3

4 5 6 L

N

L

L

N

¾

†

Strip cable to 8 mm (max. 9)

¾

†

Insert cable in the open DuoFix plug-in terminal at 45°

 

L

2 cables per terminal position possible

¾

†

To open the DuoFix plug-in terminal, press screwdriver 

downwards

Disconnecting the cable

¾

†

Use the screwdriver to push the load line connection 

opener downwards