Page 4

688 Manual 

CHAPTER 2 - OPERATIONS AND FEATURES

Overview

For the 810PS2 

S

EE

L

EVE

L™

 

 gauge, the 

M

ULTI

R

ACK

™ system 

consists of a 688M 

M

ULTI

R

ACK

  Driver Module and, a fiber optic 

interconnect  cable,  and  a  688S  (single  compartment)  or  688D 

(dual compartment) rack controller.  The gauge module is installed 

inside the 

S

EE

L

EVE

L™ and connected to alarm 4.  For the 808P2 

SeeLeveL Special gauge, only a 688M 

M

ULTI

R

ACK

™  Driver Module 

is needed.  In both cases, the fiber optic cable carries a pulsed light 

signal from the module to the rack controller to tell it to permit 

loading.  The rack controller is wired to the appropriate sockets 

for connection to the loading rack.  When the gauge detects an 

overfill situation, the pulse light signal is turned off by the module 

and the rack controller goes to non-permit, which shuts down the 

loading rack.

PERMIT

THERM B

OPTIC

THERM A

MODEL 688

OPTIC/THERMISTOR LOADING RACK CONTROLLER

MultiRack

TM

POWER

OPTIC

SIGNAL

810-X Bar

M

ULTI

R

ACK

Rack Plugs Wired

to M

ULTI

R

ACK

808-P2 S

EE

L

EVE

L S

PECIAL

or 810-PS2 S

EE

L

EVE

L P

RO

S

ERIES

 II

SHUT

UNPLUGGED

OPEN CIRCUIT

DOWN

HORN

ALARM

EMPTY

RE-ARM

MANUAL

RE-ARM

BYPASS

VALVE ERROR

SHORT CIRCUIT

PTO
ON

OFF

ENGINE ON

MODEL 815UHP

ALARM CONTROLLER

WARNING: SEE OWNERS MANUAL FOR INFORMATION

REGARDING OPERATIONAL PROCEDURES!

SPILLSTOP ULTRA

TM

PTO

UNLOAD

S

PILL

S

TOP

Controller

To loading rack

Driver Module Operation

The 688M 

M

ULTI

R

ACK

™  Driver Module contains only the optical 

transmitter for the 

M

ULTI

R

ACK

™ , since the S

PILL

S

TOP

™ module is 

built into the 808P2.  The module mounts inside the 808P2 display 

enclosure and connects to the black ground wire and yellow alarm 

wire from the 808P2.  Alarm 4 is programmed to operate the 

M

ULTI

R

ACK

™ , the same as for the 810 model.

 

 Warning:  The module must be wired correctly to ensure 

overfill protection is maintained when operated in conjunction 

with the 815-UHP S

PILL

S

TOP

 system.

Содержание MULTIRACK 688-S

Страница 1: ...60 Old Granbury Road Granbury TX 76049 CANADA Garnet Instruments 286 Kaska Road Sherwood Park AB T8A 4G7 garnetinstruments com 1 800 617 7384 Optic Thermistor Rack Control for Trucks MODEL 688 S 688 D MANUAL MUL TIRACK TM ...

Страница 2: ... CHAPTER 2 OPERATIONS AND FEATURES 4 CHAPTER 3 INSTALLATION GUIDE 7 CHAPTER 4 TROUBLESHOOTING GUIDE 10 CHAPTER 5 SERVICE AND WARRANTY INFORMATION 12 GARNET MultiRACK TM Optic Thermistor Rack Control for Trucks MODEL 688 S 688 D MANUAL 688 Manual_v5 4 06 Dec 2019 ...

Страница 3: ...nd thermistor style two wire loading racks The MULTIRACK TM will shut down the loading rack when the product level reaches the programmed shutdown point in the SEELEVEL gauge The MULTIRACK TM will withstand the vibration shock moisture and temperature extremes encountered in transport applications It is housed in a durable weatherproof housing and will operate over an ambient temperature range of ...

Страница 4: ...THERM B OPTIC THERM A MODEL 688 OPTIC THERMISTOR LOADING RACK CONTROLLER MultiRackTM POWER OPTIC SIGNAL 810 X Bar MULTIRACK Rack Plugs Wired to MULTIRACK 808 P2 SEELEVEL SPECIAL or 810 PS2 SEELEVEL PROSERIES II SHUT UNPLUGGED OPEN CIRCUIT DOWN HORN ALARM EMPTY RE ARM MANUAL RE ARM BYPASS VALVE ERROR SHORT CIRCUIT PTO ON OFF ENGINE ON MODEL 815UHP ALARM CONTROLLER WARNING SEE OWNERS MANUAL FOR INFO...

Страница 5: ...tion has two trailers then the optic portions of the two controllers are series wired just like optic probes The controller has two thermistor leads to simulate two thermistor probes and will operate with either one or both of the thermistor leads connected For two trailer applications each of the thermistor leads from the rack socket is connected to its own controller The controller simulates a t...

Страница 6: ... TM or SEELEVEL SPECIAL TM at the start of loading each compartment If any skipping of calibration points is observed discontinue loading until the problem is corrected Please refer to the manuals for these instruments for further details Installation Installation of the system consists of connecting the appropriate module into the gauge and programming alarm point 4 The controller enclosure is mo...

Страница 7: ...eak through the inside If you drill off a wire or fiber connector it will NOT be covered by warranty 5 Mount the controller enclosure using the mounting flange holes being certain to shim the enclosure away from the mounting surface with the spacers provided to allow water drainage Broken controller enclosures caused by water freezing behind the enclosure are NOT covered by warranty 6 Connect the ...

Страница 8: ...IVALENT Red Optic power Optic probe red wire Yellow Optic pulse input Optic probe yellow wire Orange Optic pulse output Optic probe orange wire Black Optic thermistor ground Optic probe black wire Thermistor probe white wire Green Thermistor lead 1 Thermistor probe black wire Green Thermistor lead 2 Thermistor probe black wire 10 For dual trailer applications wire the optic portion of the two cont...

Страница 9: ...nd then snap on the cap 14 Record the truck unit number compartment number and the level of the rack shutdown point in the IMPORTANT OPERATOR INFORMATION area on the front page of the SEELEVEL gauge users manual The truck operator must be given the owners manual upon delivery with all front page data filled in The following wiring diagram illustrates a B train with a single compartment lead equipp...

Страница 10: ...t flash If not the module is defective If it does flash the gauge alarm point 4 is not working it may need to be programmed or serviced Fiber Cable If the module produces a light pulse but it does not reach the controller replace the fiber cable Controller If the controller is non permissive check to make sure it is receiving light pulses from the fiber s Dual controllers need pulses from both fib...

Страница 11: ...ection For a thermistor rack if the diagnostic LED is on in the controller then the socket connection is good For an optic rack the pulse input and output are not monitored since the pulse width is so small the LEDs would not be visible so even though the LED is on there may still be a connection problem ...

Страница 12: ...LIMITATION ON WARRANTIES These warranties are the only warranties expressed or implied upon which products are sold by Garnet and Garnet makes no warranty of merchantability or fitness for any particular purpose in respect to the products sold Garnet products or parts thereof assumed to be defective by the purchaser within the stipulated warranty period should be returned to the seller local distr...

Страница 13: ...Page 13 688 Manual ...