GMR 21/41 Owner’s Manual
13
b
asIc
o
PeratIon
>
r
adar
t
ab
Advanced Sub Tab
Use the Advanced sub tab to set the AFC Mode and the front of boat
offset.
The available Advanced sub tab settings are:
•
AFC Mode
—sets how the scanner frequency is adjusted.
Select
Auto
to automatically adjust the scanner frequency for
optimal performance (recommended). Select
Manual
to set the
frequency manually.
To manually adjust the scanner frequency:
1. Highlight the
AFC Mode
field, and press
ENTER
.
2. Select Manual, and press
ENTER
.
3. Highlight the
Freq
button to the right of the
AFC Mode
field,
and press
ENTER
.
NOTE:
The
Freq
button is available only available if
Manual
is
selected in the
AFC Mode
field.
4. Press up or down on the
ROCKER
to adjust the scanner
frequency.
5. Press
ENTER
to accept the frequency change.
NOTE:
The Signal Strength bar graph is damped and may be
slow when responding to frequency tuning changes.
•
Signal Strength
—Shows the strength of the radar signal.
•
Front of Boat Offset
—allows you to offset the front of the
boat if you mount the radar at an angle.