190-02246-11
GI 275 Part 23 AML STC Maintenance Manual
Rev. 1
Page 5-36
5.13 Uploading Software
The
SW/Config
page is used to update the software for the GI 275 and any LRUs directly interfaced to the
GI 275. The approved software version and part numbers can be found in the most recent revision of
GI 275 Part 23 AML STC
Equipment List
(P/N 005-01208-42). Ensure the Unit ID is properly configured
prior to loading software to the GI 275. After loading software to the GI 275, configure all interfaced
LRUs.
Software updates can be accomplished via USB using the following procedure:
1. Create a Software Loader Card using the latest software and instructions available on the Garmin
2. Power on all GI 275s in the system in Configuration mode.
3. Insert the USB drive into the USB dongle or GSB 15 (if installed). A USB icon should appear on
the left of the display once the GI 275 has recognized the device. If the icon doesn’t appear after 1
minute, remove the drive and re-insert it.
4. Navigate to the
Loader Card
page (
SW/Config
→
Loader Card
).
5. Select the applicable updates or touch the
Select All
button.
6. Touch
Update Packages ( )
and then
Begin Update
. A restart is required when completed.