6
GHP 10V Installation Instructions
GHP 10V General Connection Diagram
➊
➋
➌
➍
➎
➑
➐
➏
Item Description
Important Considerations
➊
GHC 10
➋
GHC 10 data cable
Route the yellow wire to the location where you plan to install the GHC 10 (
)
➌
NMEA 2000 network
The GHC 10 and the CCU must be connected to the NMEA 2000 network using the included T-connectors
).
If there is not an existing NMEA 2000 network on your boat, you can build one using the supplied cables and
connectors (
).
➍
NMEA 2000 power cable This cable should be installed only if you are building a NMEA 2000 network. Do not install this cable if there is an
existing NMEA 2000 network on your boat (
The NMEA 2000 power cable must be connected to a 9–16 Vdc power source.
➎
CCU
Mount the CCU with the cables pointing straight down (
➏
CCU power cable
The CCU can be connected to a 12-24 Vdc power source. The black wire from the GHC 10 data cable must be
connected to the same ground as this cable (
➐
CCU interconnect cable In order for the autopilot to turn on, the yellow wire from this cable must be connected to the yellow wire from the
GHC 10 data cable.
The orange and blue wires from this cable must be connected to the alarm (
).
➑
GHP 10V Autopilot
Gateway