190-01115-01
G3X/G3X Touch Installation Manual - GEA 24 Installation
Rev. AC
Page 10-1
10 GEA 24 (EIS INTERFACE) INSTALLATION
This section contains general information as well as installation information for the GEA 24. Use this
section to mount the GEA 24 unit.
Figure 10-1 GEA 24 Unit View
10.1 Equipment Description
The GEA 24 is an input/output system used to monitor and power engine and airframe sensors for the
Experimental – Amateur Built (E-AB) and Light Sport Aircraft (LSA) markets. In a G3X Touch system,
two GEA 24 units may be installed to monitor and display engine data for twin-engine aircraft, or single-
engine aircraft with more than six cylinders. The second GEA 24 must be configured as EIS #2 as
described in
.
•
9 pin network-power connector
•
50 pin miscellaneous connector for airframe sensors
•
25 pin thermocouple input connector
•
37 pin miscellaneous connector (for airframe sensors) will provide for the following input/output
functionality:
◦
Configure analog, digital, and discrete I/O capability
◦
Output digital measurement of analog input resistive sensors
◦
Output digital measurement of analog input voltages
◦
Output digital state of discrete input sources
◦
Output frequency measurement of digital input sources
◦
Control of discrete annunciator outputs
NOTE
If a GEA 24 is installed in a system that also includes a GSU 73, the GEA 24 must be
configured as EIS #2 as described in
.
GEA 24 UNIT
011-02848-00
J243
J242
J244
J241