
190-01115-01
G3X/G3X Touch Installation Manual - Connector Installation Instructions
Rev. AC
Page 24-16
24.4.5 Shield Termination-Method B.2 (Daisy Chain-Quick Term)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together before coming to the ring terminal
(Figure 24-11). All other restrictions and instructions for the shield termination technique set forth for
Method B.1 are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure 24-11 Method B.2 (Daisy Chain-Quick Term) for Shield Termination