Page 4-104
LMM for the Kodiak 100
190-02102-00 Rev.4
4.7.13 Downloading GIA and GSA Maintenance Logs
1. Insert a FAT 32 formatted SD card into the top slot of the PFD1 before turning on
the displays
2. Apply system power to PFD1/2 and MFD in the configuration mode.
3. On the PFD1 in the System page group, use the small FMS knob to scroll to the
Diagnostics Terminal page.
4. Press the LG2CRD softkey at the bottom of the PFD1. Verify the softkey text
grays out. This indicates the recording function is active and all text that is dis-
played in the OUTPUT window will be saved to the card.
5. Enable the cursor by pressing the FMS knob, select GIA1 in the LRU drop down
menu and then press the ENT key to select it.
6. Skip the SERVO box and move the cursor to the COMMAND box and select
View Maintenance Log in the drop down menu then press the ENT key. The error
log data will be displayed in the OUTPUT box. If you see the ‘more... press any
key to continue’ text at the bottom of the screen, you may need to reselect View
Maintenance Log for GIA data to allow it to continue scrolling down the screen
(pressing any key will not continue, disregard the text instruction you to do so).
Continue to scroll through all the OUTPUT data until you see the text End of Fault
Log.
7. Move the cursor back to the LRU box, select GIA2 in the LRU drop down menu
and then press the ENT key to select it.
8. Skip the SERVO box and move the cursor to the COMMAND box and select
View Maintenance Log in the drop down menu then press the ENT key. The error
log data will be displayed in the OUTPUT box. If you see the ‘more... press any
key to continue’ text at the bottom of the screen, you may need to reselect View
Maintenance Log for GIA data to allow it to continue scrolling down the screen
(pressing any key will not continue, disregard the text instruction you to do so).
Continue to scroll through all the OUTPUT data until you see the text End of Fault
Log.
9. If you need to download Servo fault logs (usually done at the request of Garmin
Product Support), perform the following steps. Otherwise, skip to step 10.
a) In the LRU box, you may select either GIA1 or GIA2.
b) In the SERVO box, choose a servo using the FMS knobs. Each servo con-
tains two logs, one in the Monitor (MON) processor and one in the Control
(CTL) processor. You must download both for each servo separately.
c) In the COMMAND box, select View Maintenance Log and press the ENT key.