User Guide
EdgeLens | INT40G2XX44 | 4.22.1
Taps Settings
The following configuration options may be displayed, modified, enabled or disabled.
Tap Mode
Reverse Bypass
Fail Mode
Revertive
LFP
Coupled
1. Edit the Tap Settings, by placing the cursor on any tap and double-press the left mouse button.
The Tap panel will be displayed.
2. Select Edit Tap Settings.
The Configure Inline Appliance panel will be displayed.
3. Select the Tap Mode.
Active
Allows the tap to automatically switch from inline to bypass if an issue occurs
with the primary inline appliance port(s) and secondary inline appliance port(s),
loss of link or heartbeats. The default switching action from inline to bypass
is defined by the system as, from the primary inline appliance, to the secondary
inline appliance, to bypass. The default switching action from bypass to inline
is defined by the system as, from bypass, to the secondary inline appliance.
Switching from the secondary inline appliance to the primary inline appliance
may be accomplished via two methods. Select the Switch to Primary option
or enable Revertive. If revertive is enabled, then the system will switch from
bypass to the primary inline appliance if it is recovered first.
Figure 2 Primary-Secondary Tap (Primary Inline)
Garland Technology | 716.242.8500 | www.garlandtechnology.com
Copyright © 2022 Garland Technology, LLC. All rights reserved.
24