9. Select Cancel to return the Syslog Configuration panel.
Syslog Test
1. Select Syslog Test.
The GUI message will be displayed,”Syslog Test Successful!”.
2. Verify the Syslog Test Message on the Syslog server.
SNMP
The system supports an IPv4 or IPv6 address for SNMP. If IPv4 is desired, then an IPv4
management interface must be assigned. If IPv6 is desired, then an IPv6 management interface
must be assigned. The system allows for an IPv4 and IPv6 management interface to be assigned
simultaneously.
The following SNMP configuration options are supported:
V2 Read/Write
V2 Read Only
V3 Auth Type
MD5 / SHA
V3 Priv Protocol
DES / AES
1. Select SNMP.
The SNMP Configuration panel will be displayed.
2. Select Edit Configuration.
3. Select Enable SNMP Config.
4. Enter the desired Access Port number or use the default, 161.
5. Enter the desired Trap Port number or use the default, 162.
6. Enter the IPv4 or IPv6 Address.
7. Select the desired Protocol, (V2 Read/Write or V2 read Only).
8. Enter the desired V2 Community Password.
9. Select the desired Protocol, (V3).
10. Enter the desired V3 User.
11. Enter the desired V3 Auth Password.
12. Enter the desired V3 Priv password.
13. Select Save.
14. Select Cancel to return the SNMP Configuration panel.
SNMP Test
1. Select SNMP Test.