User Guide

PacketMAX |

GAA10G20AC | 4.23.1

3. Select Enable SNMP Config.

4. Enter the desired Access Port number or use the default, 161.

5. Enter the desired Trap Port number or use the default, 162.

6. Enter the IPv4 or IPv6 Address.

7. Select the desired Protocol, (V2 Read/Write or V2 read Only).

8. Enter the desired V2 Community Password.

9.  Select the desired Protocol, (V3).

10. Enter the desired V3 User.

11. Enter the desired V3 Auth Password.

12. Enter the desired V3 Priv password.

13. Select Save.

14. Select Cancel to return the SNMP Configuration panel.

 SNMP Test

1. Select SNMP Test.

The GUI message will be displayed,”Test Successful!”.

2. Verify the SNMP Test Message on the MIB Browser.

 

Export Configuration

This option creates a configuration file (exportCfg.json) that may be used to recover a unit. The

exportCfg.json file may be renamed if desired. The exportCfg.json file does not contain Usernames,
Passwords, Groups or Network Settings.

1. Select Export Configuration.

The Export Configuration panel will be displayed.

2. Select Export.

The exportCfg.json file will be downloaded to the default download destination of the browser.

 

Import Configuration

This option allows a previously created configuration file (exportCfg.json) to be uploaded to the unit. The

Chassis Model is the only option that is considered and must match, otherwise the unit will reject the
exportCfg.json file.

1. Select Import Configuration.

The Import Configuration panel will be displayed.

Garland Technology  |  716.242.8500  |  www.garlandtechnology.com
Copyright © 2023 Garland Technology, LLC. All rights reserved.

Содержание GAA10G20AC

Страница 1: ...User Guide GAA10G20AC 02 2023 Release Version 4 23 1...

Страница 2: ...consent of Garland Technology All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The purchased products services and features are stipu...

Страница 3: ...rs 8 Groups 9 Authentication 9 Local Authentication Disable 10 Local Authentication Enable 10 TACACS Primary Authentication 10 TACACS Test 10 TACACS Ping Test 10 TACACS Secondary Authentication 11 TAC...

Страница 4: ...icy 25 Config Map 26 Ingress 27 Filters 27 Egress 28 Egress Filter 29 Config Map Save 30 Modify a Config Map 31 Delete Config Map 32 Config Map Priority 32 Method 1 33 Method 2 33 Enable Disable Confi...

Страница 5: ...shboard provides access to the Packet Broker Port Info and System configuration options by selecting the desired option in the top menu bar These options are covered in detail per their specific secti...

Страница 6: ...3 Left Up Arrow Link LED Port 4 Left Down Arrow Link LED Port 5 Left Up Arrow Link LED Port 6 Left Down Arrow Link LED Port 7 Left Up Arrow Link LED Port 8 Left Down Arrow Link LED Port 9 Left Up Arr...

Страница 7: ...xport Configuration Admin Import Configuration Network Settings Software Upgrade Date Time Reboot Syslog 1 Select System on the Dashboard Menu bar The System panel will be displayed The system configu...

Страница 8: ...The General System Settings panel will be displayed 2 Select Edit Configuration 3 Enter the desired Chassis Name 4 Enter the desired Key Press Timeout 5 Select Save to save updates 6 Select Cancel to...

Страница 9: ...r a user or group of users A group may be used for local or TACACS authorization In Use true means that there is at least one local user assigned to the group If a group is used by TACACS the In Use w...

Страница 10: ...y be disabled provided that TACACS authentication primary or secondary has previously been enabled 2 Select Save Local Authentication Enable 1 Select Local Authentication 2 Select Save TACACS Primary...

Страница 11: ...updates 5 Select Cancel to return the Admin Settings panel TACACS Test This option may be used to verify the authentication of a TACACS user password and authorization group The TACACS Test option wi...

Страница 12: ...planning have not been performed The default system network configurations are as follows IPv4 enabled IPv4 address 10 10 10 200 IPv4 gateway 10 10 10 1 IPv6 is disabled Via the GUI the following opti...

Страница 13: ...e files are corrupted the unit will abort the upload 1 Select Add SSL Certificate The Select Certificate and Select Key File panel will appear 2 Select Choose File for Select Certificate 3 Select the...

Страница 14: ...panel will be displayed Timezone 1 Select Edit Settings 2 Select the desired Timezone using the pull down panel 3 Select Save 4 Select Cancel to return to the Date Time Settings panel UTC 1 Select Ed...

Страница 15: ...return to the Date Time Settings panel NTP Authentication Symmetric The system supports an IPv4 or IPv6 address for NTP timing If IPv4 is desired then an IPv4 management interface must be assigned If...

Страница 16: ...ect Cancel to return the Syslog Configuration panel Syslog Test 1 Select Syslog Test The GUI message will be displayed Syslog Test Successful 2 Verify the Syslog Test Message on the Syslog server SNMP...

Страница 17: ...figuration This option creates a configuration file exportCfg json that may be used to recover a unit The exportCfg json file may be renamed if desired The exportCfg json file does not contain Usernam...

Страница 18: ...An Upgrade Guide is created as part of the standard documentation for each release Please refer to the Upgrade Guide for the procedure Reboot This option allows the unit to be rebooted The traffic wil...

Страница 19: ...modified enabled or disabled under the Packet Broker panel Configuration Maps Load Balance Groups Tunnels Load Balance Policy Filter Templates 1 Select Packet Broker on the Dashboard menu bar Garland...

Страница 20: ...the original packet The l2GRE header segments consists of Ethernet II IPv4 and l2GRE as shown below Original Packet l2GRE Encapsulated Packet 1 Select Tunnels The Tunnels panel will be displayed 2 Sel...

Страница 21: ...ter the Remote IP Address VXLAN Header DIP 9 Enter the Remote MAC Address VXLAN Header DMAC 10 Enter the Key 1 16777215 The default VXLAN Header SMAC is automatically defined by the system There are f...

Страница 22: ...nts are removed from the packet l2GRE Encapsulated Packet l2GRE Decapsulated Packet 1 Select Tunnels The Tunnels panel will be displayed 2 Select Create Tunnel The Create Tunnels panel will be display...

Страница 23: ...Header DIP 8 Enter the Remote IP Address VXLAN Header SIP 9 Enter the Key 1 16777215 The default VXLAN Header SMAC is automatically defined by the system There are five predefined SMACs 10 Select Adv...

Страница 24: ...ptions were modified 1 Select Filter Templates on the Packet Broker Configurations panel The Filter Templates panel will be displayed 2 Select Create Template The Create New Filter Template panel will...

Страница 25: ...oups will appear on the Create Config Map panel 1 Select Load Balancing Groups The Load Balancing Groups panel will be displayed 2 Select Create Group The Create New Load Balance Group panel will be d...

Страница 26: ...licy panel will be displayed 2 Select or deselect the desired load balancing policy options 3 Select Save to save updates 4 Select Cancel to disregard changes Config Map Config maps are unidirectional...

Страница 27: ...ace the cursor in the Description panel and enter the description optional 8 Select the Check to apply updates Ingress 1 Add an ingress port by placing the cursor on the desired port Select with the l...

Страница 28: ...may be selected and moved up or down depending on priority preference Figure 2 Filter Figure 3 Filter System Considerations 2 Filter templates may be modified by selecting the green filter icon for t...

Страница 29: ...use button Drag the load balancing group to the Egress panel and release Ports may be added or removed from any load balancing group If ports are added or removed from a previously created load balanc...

Страница 30: ...e selected Select with the left mouse button Drag the filter template to the Port XX Egress Filters panel and release The filter template will become an actual egress filter once the config map is sav...

Страница 31: ...Accept once all desired options have been modified Config Map Save 1 Select Save to save the current configuration The Save this configuration May take a few seconds panel will be displayed 2 Select...

Страница 32: ...stics 3 Select the View Counts icon to display individual statistics 4 Select Refresh Counts to refresh the statistics 5 Select Clear Counts to clear and refresh the statistics 6 Select the Egress Fil...

Страница 33: ...In this case the config map with the highest priority will be considered first In the following example there are three config maps with ingress port 3 The Traffic_A config map is the highest priority...

Страница 34: ...to disregard 5 Select Save to save updates Enable Disable Config Map Config maps may be enabled or disabled as desired If a config map is enabled it is in the database and available for traffic If a...

Страница 35: ...h for the config map in the Enable column The red dash will change to a green check 2 Select Save 4 Port Info The following configuration options may be displayed or modified under the Port Info panel...

Страница 36: ...escription panel will be displayed 2 Place the cursor in the description field and enter the new description 3 Select Set to save updates 4 Select Cancel to return to the Port Configuration panel Set...

Страница 37: ...tion is only available for packet brokers ports The packet broker section consists of ports 1 through 12 1 Select the VLAN Tag enable option for the desired port 2 Enter the desired VLAN ID 1 4094 3 S...

Страница 38: ...User Guide PacketMAX GAA10G20AC 4 23 1 Garland Technology 716 242 8500 www garlandtechnology com Copyright 2023 Garland Technology LLC All rights reserved...