User Guide
PacketMAX |
GAA10G20AC | 4.23.1
3. Select Enable SNMP Config.
4. Enter the desired Access Port number or use the default, 161.
5. Enter the desired Trap Port number or use the default, 162.
6. Enter the IPv4 or IPv6 Address.
7. Select the desired Protocol, (V2 Read/Write or V2 read Only).
8. Enter the desired V2 Community Password.
9. Select the desired Protocol, (V3).
10. Enter the desired V3 User.
11. Enter the desired V3 Auth Password.
12. Enter the desired V3 Priv password.
13. Select Save.
14. Select Cancel to return the SNMP Configuration panel.
SNMP Test
1. Select SNMP Test.
The GUI message will be displayed,”Test Successful!”.
2. Verify the SNMP Test Message on the MIB Browser.
Export Configuration
This option creates a configuration file (exportCfg.json) that may be used to recover a unit. The
exportCfg.json file may be renamed if desired. The exportCfg.json file does not contain Usernames,
Passwords, Groups or Network Settings.
1. Select Export Configuration.
The Export Configuration panel will be displayed.
2. Select Export.
The exportCfg.json file will be downloaded to the default download destination of the browser.
Import Configuration
This option allows a previously created configuration file (exportCfg.json) to be uploaded to the unit. The
Chassis Model is the only option that is considered and must match, otherwise the unit will reject the
exportCfg.json file.
1. Select Import Configuration.
The Import Configuration panel will be displayed.