6.41 Set default parameters (set_default)
Restore the factory default settings for all parameters including system user name and password.
Command does not restore rs232 port speed.
Example:
The factory default settings are:
IP address: 10.10.10.200
Net mask: 255.255.255.0
Gateway: 10.10.10.200
hb_interval : 5 ms
hb_holdtime: 20 ms
enable snmp traps: disabled all snmp trap -
snmp server ip: 192.168.0.6
snmp version: 1
Session expired time: 900 sec
WEB https: enabled
TFTP server ip: 192.168.0.6
SNMP user: admin
SNMP password: gtadmin1
Unit name: M40GBP
TFTP root: tftpboot
Two port link: disabled
Expire state: Bypass
Keep heartbeat active mode: disabled
Management port: enabled
Heartbeat active mode: ON
System user: admin
System user password: gtadmin1
Heartbeat packet transmit direction: mon0
Heartbeat packet fail criteria: unidir
Ethernet Management port parameters: auto
Remote log state: disabled
NTP: off
Telnet: off
Remote log server IP: 192.168.0.6
NTP server IP: 192.168.0.6
Timezone: UTC
Tacacs state: off
Tacacs server IP: 192.168.0.6
WEB user name: admin
WEB user password: gtadmin1
Tacacs secret key: default_tac_key
M40GBP$ set_default
command succeeded.
M40GBP$