USER GUIDE
EdgeSafe 40G Bypass Modular Network TAP | M40GBP
Version 1.6 Page 37 of 159
Garland Technology reserves the right to make changes without further notice to any products or data herein to improve reliability, function or design.
Confidential -This document is
Garland Technology
.'s property. This document may not be copied, duplicated and transferred to electronic or mechanized
media or used for any other purpose, including any part thereof or attachment thereto, except as authorized in advance and in writing by
Garland Technology.
6.10 hb_holdtime (hb_holdtime)
The M40GBP monitors the received packets on monitor port1, if heartbeat packets do not arrive within
“hb_holdtime” msec, the M40GBP will set the Active Bypass to
Bypass/TAP/Linkdrop
mode, depend
on active switch expire state .
To secure reliable detection of Application failure, the " hb_holdtime " value should be at least 3 times
the “hb_interval” parameter value. (default - 20, min - 10, max - 50000)
The " hb_holdtime " value is preserved after reset and power off events.
Example:
6.11 Keep heartbeat active mode (keep_hb_act_mode)
When “ keep_hb_act_mode” is ON the state of
is preserved after reboot or after
power on events. When the keep_hb_act_mode is OFF the state of
is
automatically set to ON after reboot or after power on.
Default value of the keep_hb_act_mode is OFF ( disabled).
Example:
M40GBP$ get_hb_holdtime
hb_holdtime: 20 ms.
command succeeded.
M40GBP$ set_hb_holdtime 10
command succeeded.
M40GBP$ get_hb_holdtime
hb_holdtime: 10 ms.
command succeeded.
M40GBP$
M40GBP$ get_keep_hb_act_mode
keep_hb_act_mode: off.
command succeeded.
M40GBP$ set_keep_hb_act_mode on
command succeeded.
M40GBP$ set_keep_hb_act_mode off
command succeeded.