Document Number: GAR_IS_4601787 rev 0 (12/15) 5
Section 2
Installation Procedures
n
Warning
Always disconnect electrical power before removing panels.
Broiler temperature extremely high, be very careful.
1. Lower the top platen
and remove the left
lower side panel, four (6)
screws using Phillips #2
screwdriver.
2. Remove the 2 existing screws from the SIB
board using a phillip screwdriver. Store screws and
washer in safe place.
3. Starting from right to left, disconnect the first
thermocouple plug from the SIB board, and connect
it to the noise reduction board (NRB). Repeat
process for every wire.
first one install into the noise reduction board
all plugs installed into the noise reduction board
4. Now move the noise reduction board (NRB)
aside and start connecting the plug from the NRB
to the SIB board. Same order as the previous plugs
connected, right to left. Repeat process for every
wire plug.
IMPORTANT NOTE
Tug each wire plug to make sure all connectors are firmly
attached and secure.
Noise Reduction Board (NRB) Installation Procedure