Technical Data
109030
15
4.3.2
Device data - Diaphragm pumps
Parameter
Unit
MPC 101 Z
MPC 301 Z
Pumping speed 50/60 Hz
DIN 28432
at speed of 1500 rpm
m
3
/ h
1 / 1.1
2.3 / 2.5
l / min
16.7 / 18
38 / 41
Ultimate pressure
at speed of 1500 rpm
mbar
8
Ultimate pressure
with gas ballast
at speed of 1500 rpm
18
Max. inlet pressure
bar
1
Max. outlet pressure
1
Suction- / pressure port
-
Hose nozzle DN 8
for hose inside diameter 8 mm
Ambient temperature
°C
+ 10 to + 40
Max. operating gas temperature
+ 60
Bearing
-
maintenance-free
Noise level
DIN EN ISO 2151
dB (A)
44
Voltage
V
230 (115)
100-120 / 200-240
switchable
Frequency
Hz
50/60
Motor power
kW
0.06
0.18
Operating mode
-
S 1
Type of protection
DIN EN 60529
IP 54
Motor / Class of insulation
DIN EN 600034-1
BLDC / F (160°C)
Dimensions (W/D/H)
mm
195 / 235 / 145
230 / 265 / 169
Weight
kg
6.5
11.2
Order numbers for :
-
- Diaphragm pump 230 V
412522-08
-
- Diaphragm pump 115 V
412522-09
-
- Diaphragm pump
100 / 115 / 230 V switchable
-
412722-09
The information presented in this material is based on technical data and test results of nominal units. It is believed
to be accurate and reliable and is offered as and aid to help in the selection of products.
It is the responsibility of the user to determine the suitability of the product for the intended use and the user as-
sumes all risk and liability whatsoever in connection therewith. Gardner Denver Thomas GmbH does not warrant,
guarantee or assume any obligation or liability in connection with this information.