13-17-618 Page 67
10-1
SECTION 10
INLET CONTROL VALVE
INLET CONTROL VALVE
–
This device is located at the intake flange of the compressor. During
compressor stoppage, planned or accidental (e.g. power failure), it blocks off the compressor intake and
allows it to remain pressurized and ready for quick re-start. A spring-loaded check feature is provided as
added insurance against air or oil backflow
During compressor operation, the underside of the poppet is vented to atmosphere via a 3-way solenoid
valve, allowing the poppet to fall (open) and feed fresh air to the compressor inlet-the spring loaded check
feature is pushed open by a very small pressure differential resulting from the incoming air stream.
During stopped operation modes (e.g. commanded from keypad or initiated by protective shutdown), the
compressing the spring loaded check feature and blocking-off the compressor intake.
Refer to Parts List 13-17-500 for spare parts.
Figure 10-1
– INLET CONTROL VALVE (BODY)
Содержание VST55-90B
Страница 33: ...13 17 618 Page 32 4 5 Figure 4 2 PIPING AND INSTRUMENTATION ILLUSTRATION 300ETK797 C Ref Drawing ...
Страница 67: ...13 17 618 Page 66 9 2 Figure 9 1 MINIMUM DISCHARGE PRESSURE CHECK VALVE ...