Installation
5
Installation
5.1 Preparation of installation
Ensure the following conditions:
• Central vacuum unit freely accessible from all sides
• Do not close or cover ventilation grids and openings
• Sufficient space for installing and removing pipes and for maintenance work, particularly for the installa-
tion and deinstallation of the machine
• No influence by external vibrations
• Hot exhaust air from other machines may not be sucked in the cooling system
The following parts of the unit must be easily accessible:
• Control box (Fig. 3/4)
• Ventilation grid at the rear, the solenoid valve (Fig. 3/2) is below it
• Vacuum connection
• Oil filling point (Fig. 2/H), oil sight glasses (Fig. 2/I, /I
1
) and oil drains (Fig. 2/K, /K
1
)
5.2 Installation
The installation of the central vacuum unit requires specific conditions.
It is specifically recommended to have the installation performed by skilled staff and to follow the instruc-
tions described below.
DANGER
Risk of explosion!
The unit is not designed for the installation in potentially explosive environments.
There is a serious danger of explosion.
Ø
Do not place the central vacuum unit close to flammable products.
Ø
Do not install the central vacuum unit in areas with increased percentage of
oxygen.
NOTICE
Property damage caused by improper installation!
Improper erection and installation can damage the machine.
Ø
The machine may only be operated when it is set up horizontally
(Max. inclination: 5 ° in all directions).
Ø
Secure the machine against tipping over and falling.
Ø
The floor must be plane and even.
Ø
The bearing surface must be designed to be able to carry the weight of the
machine.
NOTICE
Property damage from overheating!
The compressor may overheat and be damaged due to an insufficient cooling
capacity.
Ø
Ensure for a good aeration and venting of the installation room.
Observe the ambient temperature: min. +5 °C, max. +40 °C
Ø
The cooling air inlets and the cooling air outlets must be at least 30 cm away
from the adjacent walls. Cooling air coming out must not be sucked in again.
Ø
For maintenance work, provide a clearance of at least 40 cm around the
compressor.