22
|
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Maintenance and repair
7
Maintenance and repair
DANgER
Danger of death from touching live parts!
Before maintenance work disconnect the machine
by pressing the main switch or unplugging it and
ensure that it cannot be turned on again.
WARNINg
Hot surfaces
During maintenance work there is the danger of
getting burnt on hot components (Fig. 2/Q... 4/Q)
of the machine.
Wait for the machine to cool down.
7.1 Ensuring operational safety
Regular maintenance work must be carried out in order to ensure operational safety.
Maintenance intervals also depend on the operational demands on the machine.
With any work observe the safety instructions described in Section 2.8 "Safety notes for installation, com-
missioning and maintenance".
The whole plant should always be kept in a clean condition.
7.2 Maintenance work
Interval
Maintenance activities
Section
Monthly
Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.
—
Monthly
Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.
—
Monthly
Clean the control valve and ventilation slots on the machine
and the motor cooling ribs.
—
Monthly
Check the oil level
7.2.1
5,000 h
Change the oil
Monthly/ every 6 months
C-VLR 60: Clean or replace filter cartridge
7.2.2
Depending on how dirty the
discharged medium is
C-VLR 100
- 251: Clean micro filter
At least once a year
Check for clutch wear
7.2.3
Содержание Elmo Rietschle C-VLR 60
Страница 31: ......