13-21-611 Page 68
5-3
Dew-Point Temperature vs. Ambient Temperature
(100% Relative Humidity)
40
50
60
70
80
90
100
110
120
130
140
150
160
170
180
190
200
210
220
230
20
30
40
50
60
70
80
90
100
110
120
Ambient Temp. F
Dew
-P
o
in
t T
em
p
. F
100 psig
125 psig
150 psig
175 psig
Figure 5-1
– DEW POINT CHART
F
Figure 5-2
– DEW POINT CHART
C
These charts are easily used by reading the ambient temperature along the bottom axis of the chart and then
reading the appropriate pressure curve to determine the corresponding dew-point temperature on the left axis of
the chart. The compressor discharge temperature must be maintained at a minimum of
10
F above this dew-
point
temperature to prevent condensation accumulation in the lubricant reservoir. These charts assume 100%
relative humidity.
20
30
40
50
60
70
80
90
100
110
-10
-5
0
5
10
15
20
25
30
35
40
45
50
D
e
w
-P
o
in
t
T
e
m
p
.
C
Ambient Temp. C
Dew-Point Temperature vs. Ambient Temperature
(100% Relative Humidity)
6.9 bar
8.6 bar
10.4 bar
12.1 bar
Содержание ELECTRA-SAVER G2
Страница 11: ...13 21 611 Page 10 1 3 Figure 1 4 COMPRESSOR MOTOR SIDE Figure 1 5 COOLER RESERVOIR SIDE 309EBD797 B Ref Drawing...
Страница 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Страница 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Страница 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Страница 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Страница 71: ...5 5 13 21 611 Page 70 Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER 318EBD797 00 Ref Drawing...
Страница 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...