16 DECLARATION OF CONFORMITY 

 

VARO N.V.   -  

  Joseph Van Instraat 9  -  BE2500 Lier  -  BELGIUM, declares that,

 

Product: 

SUBMERSIBLE PUMP 550W 

Trade mark: 

POWERplus 

Model: 

POWXG9513 

is in conformity with the essential requirements and other relevant provisions of the applicable 
European  Directives,  based  on  the  application  of  European  harmonized  standards.  Any 
unauthorized modification of the apparatus voids this declaration. 

European Directives (including, if applicable, their amendments up to the date of signature); 

2011/65/EU 
2014/35/EU 
2014/30/EU 

European harmonized standards (including, if applicable, their amendments up to the date of 
signature); 

EN60335-1 : 2012 
EN60335-2-41: 2003  
EN55014-1 : 2006 
EN55014-2 : 2015 
EN61000-3-2 : 2014 
EN61000-3-3 : 2013 

Keeper  of  the  Technical  Documentation  :  Philippe  Vankerkhove,   VARO 

– Vic.  Van Rompuy 

N.V. 

The undersigned acts on behalf of the company CEO, 

 

Hugo Cuypers 
Regulatory Affairs 

– Compliance Manager 

23/02/2018 

Содержание POWERplus POWXG9513

Страница 1: ...BEFORE START UP NOTE THE FOLLOWING 3 7 INSTALLATION 3 8 SETTING TO WORK 4 8 1 Venting the pump before use 4 8 2 Setting the ON OFF operating point 4 9 CLEANING AND MAINTENANCE 4 9 1 Maintenance guidel...

Страница 2: ...e plug 5 floating switch 6 carrying handle 7 cable clamp 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the p...

Страница 3: ...cted from moisture If there is danger of flooding the electrical connections must be taken to higher ground Circulation of aggressive fluids as well as the circulation of abrasive materials must be av...

Страница 4: ...15 seconds before the pump to start 8 2 Setting the ON OFF operating point The ON and OFF operating point of the float switch can be set by adjusting the float switch in its latching holder Before yo...

Страница 5: ...h clear water 9 2 Cleaning the impeller If excessive deposits collect in the pump case you must dismantle the bottom part of the pump as follows 1 Remove the intake cage from the pump case 2 Clean the...

Страница 6: ...acity by dirty and abrasive water Clean inlet sieve Clean pump and replace worn out parts Pump switches off after short operating period Thermal cutout stops pumps due to dirty water Water too hot The...

Страница 7: ...damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage on...

Страница 8: ...dards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 35 EU 2014 30 EU Eu...

Отзывы: