11.3.2 Command summary
Command
Example
Effect
AW
AW
Save changes.
CL
CL
Clear configuration.
GT
GT1
Enable Ethernet messages.
GR
GR
Clear any error conditions
EY
EY65,66
Set webpage password to 'AB'.
VR
VR
Read the firmware version.
VL
VL1,0,0.5
Set the rating of channel 1 to 0.5A.
RS
RS2,65
Set channel 2 to 65% brightness
continuous.
RW
RW1,50
Set channel 1 to 50% switch mode.
RU
RU1,75,25
Set channel 1 to selected mode at
75% and 25%.
RT
RT2,3,4,50
Set channel 2 to 3ms pulses, delayed
by 4ms at 50% brightness.
RP
RP1,2
Output channel 1 is triggered using
output 2
RE
RE1,3
Set channel 1 to ignore lighting errors
and not prompt for the current rating of
a light when it is connected.
TT
TT1,1ms
Set internal triggers every 1ms.
TR
TR2
Trigger channel 2.
ST
ST2
Show configuration for channel 2.
—