RTxxx LED lighting controllers - User Manual
trg is displayed. Press the SEL button.
Use the
p
and
q
buttons to select the trigger
(
IP1 or IP2) you want to set up, and press the
SEL button.
To set the trigger polarity so that it is active high,
press the
SEL button with F P displayed.
Or...
If you wish to set the trigger polarity so that it is
active low, use the
p
and
q
buttons to select
F-P and press the SEL button.
To set the error detection, press the SEL button
with F E displayed.
Or...
—
40
—
RTxxx LED lighting controllers - User Manual
If you wish to disable the error detection, use
the
p
and
q
buttons to select
F-E
, and press
the
SEL
button.
Pulsed operation is set up on the RT200.
9.7
Setting time periods
When the RT200 requires you to enter a numeric value, the right hand digit
flashes to indicate you can use the
p
and
q
buttons to change the value.
To set pulse delay, retrigger, and pulse width values a scheme is used
where the exponent (power of 10) of the value is set. The exponent values
are as follows:
Exponent
value
Multiplier
Number
format
Range of values
E-2
0.01
9.99
Values are displayed in
seconds from 10ms to 5s in
steps of 10ms.
E-3
0.001
999.
Values are displayed in
milliseconds from 1ms to
999ms in steps of 1ms.
E-4
0.0001
99.9
Values are displayed in
milliseconds from 0.1ms to
99.9ms in steps of 0.1ms.
E-5
0.00001
9.99
Values are displayed in
milliseconds from 0.01ms to
9.99ms in steps of 0.01ms.
E-6
0.000001
999.
Values are displayed in
microseconds from 1μs to
999μs in steps of 1μs.
Note:
The permitted range of values for pulse delay, pulse width, and
retrigger time is given in
Section 13, Reference information
, or as limited
by the operating conditions of the light.
—
41
—