RTxxx LED lighting controllers - User Manual
9.4
Setting up switched output
Switched output is when the light remains on for as long as there is a signal
on the trigger input. Press and hold
SEL
for one second ,
CH1
is
displayed. Use the
p
and
q
buttons to select the channel you want to set
up, and follow the keystrokes below:
The channel you want to set up is displayed.
Press the
SEL
button.
Use the
p
and
q
buttons to select
SOn
and
press the
SEL
button.
bri
is displayed. Press the
SEL
button to select
the light's intensity.
Use the
p
and
q
buttons to set the intensity
from 1% to 99.9%. The default setting is 50%.
Press the
SEL
button.
trg
is displayed. Press the
SEL
button.
—
34
—
RTxxx LED lighting controllers - User Manual
Use the
p
and
q
buttons to select the trigger
(
IP1
or
IP2
) you want to set up, and press the
SEL
button.
To set the trigger polarity so that it is active high,
press the
SEL
button with
F P
displayed.
Or...
If you wish to set the trigger polarity so that it is
active low, use the
p
and
q
buttons to select
F-P
and press the
SEL
button.
To set the error detection, press the
SEL
button
with
F E
displayed.
Or...
If you wish to disable the error detection, use
the
p
and
q
buttons to select
F-E
, and press
the
SEL
button.
Switched output is set up on the RT200.
—
35
—