RPc,p
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
p
= trigger input (1 or 2)
This command can be used to override the state of an input. The
override is cancelled as soon as an edge is detected on the
input.
12.3.3
Command summary
Command
Example
Effect
AW
AW
Save changes.
CL
CL
Clear configuration.
GT
GT1
Enable Ethernet messages.
GR
GR
Clear any error conditions
EY
EY65,66
Set webpage password to 'AB'.
VR
VR
Read the firmware version.
VL
VL1,0,0.5
Set the rating of channel 1 to 0.5A.
RS
RS2,65
Set channel 2 to 65% brightness
continuous.
RW
RW1,50
Set channel 1 to 50% switch mode.
RU
RU1,75,25
Set channel 1 to selected mode at
75% and 25%.
RT
RT2,3,4,50
Set channel 2 to 3ms pulses, delayed
by 4ms at 50% brightness.
RP
RP1,2
Output channel 1 is triggered using
output 2
RE
RE1,3
Set channel 1 to ignore lighting
errors and not prompt for the
current rating of a light when it is
connected.
TT
TT1,1ms
Set internal triggers every 1ms.
—
63
—