RC1xx - User Manual
Simulate an input trigger
TR1
This command simulates an input trigger. If the RC120 is in pulse
mode, it pulses the output once.
Enable Ethernet messages
This command enables or disables Ethernet messages. Type in:
GTm
Where:
m
= 0 to disable Ethernet messages, and
m
= 1 to enable Ethernet messages.
When Ethernet messages are enabled, any error reports are sent to
the most recent UDP or TCP/IP address from which a command
has been received. These messages take the form:
Evtc,e
Where:
c
— 1 for events concerning the light output, otherwise 0
e
— the event value (see
)
Clear any errors
Use this command to read the last event or error code when
Ethernet messaging has been disabled:
GR
Any error displayed on the RC120 is cleared. If this was a lighting
error, the unit resumes auto-sensing. If there are no outstanding
events or errors, the ‘
>
’ prompt is returned.
Set/Clear the webpage password
This command sets the webpage password. Up to six characters
can be chosen. Type in:
EYasc1,asc2,asc3,asc4,asc5,asc6
Where:
asc1
to
asc6
are decimal ASCII values for the letters of your
password
For example, a value of 65 is ‘A’, 66 is ‘B’ and so on up to 90 for ‘Z’.
Note:
When you use this password to access the RC120 through the
webpage, you must use the actual characters and not the ASCII
values. Use upper case characters and do not enter commas or
spaces.
—
35
—