Set switched mode
This command sets the output to switched mode and allows the
brightness to be set:
RW1,s,w,r
Where:
s
= brightness setting in percent (0 to 999)
w
= typical pulse width in ms (optional)
r
= likely period in ms (optional)
The
w
and
r
parameters are optional and should only be used when
the expected pulse width is >100ms and/or the period is >5 seconds.
w
/
r
gives the expected duty cycle.
Set automatic sensing of light characteristics
Sets the maximum brightness to be used when automatically sensing
the characteristics of the light connected.
PQ1,0
PQ1,m
PQ
Where:
m
= maximum expected brightness (50% to 999%)
Setting
m
= 0 turns off automatic sensing. The
PQ
command returns
the current maximum brightness for automatic sensing.
10.4 Command summary
Command
Example
Effect
AW
AW
Save changes.
CL
CL
Clear configuration.
GT
GT1
Enable Ethernet messages.
GR
GR
Clear any error conditions.
EY
EY65,66
Set web page password to ‘AB’.
VR
VR
Read the firmware version.
VL
VL1,0,0.5
Set the light to 0.5A.
RS
RS1,65
Set the unit to 65% brightness
continuously.